Summary of Contents for National Instruments CompactRIO cRIO-9035
Page 1
GETTING STARTED GUIDE NI cRIO-9035 Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA This document describes how to begin using the NI cRIO-9035 and NI cRIO-9035 Sync. In this document, the NI cRIO-9035 and NI cRIO-9035 Sync are inclusively referred to as the cRIO-9035.
Safety Guidelines Caution Do not operate the cRIO-9035 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair.
Caution To ensure the specified EMC performance, you must use an isolated cable with the RS-485 serial port, such as NI part number 184428-01. Caution To ensure the specified EMC performance, the length of any cable connected to the video and V2 ports must be no longer than 3 m (10 ft). The length of any cable connected to the RS-232 and RS-485 ports must be no longer than 30 m (100 ft).
Installing Software on the Host Computer Before using the cRIO-9035, you must install the following application software and device drivers on the host computer in this order: Sequence cRIO-9035 cRIO-9035 Sync LabVIEW 2014 SP1 or later LabVIEW 2016 or later LabVIEW Real-Time Module LabVIEW Real-Time Module 2016 or 2014 SP1...
Page 10
Table 3. NI Power Supplies Power Supply Part Number NI PS-15 Industrial Power Supply 781093-01 (24 VDC, 5 A, 100 VAC to 120 VAC/200 VAC to 240 VAC input) NI PS-10 Desktop Power Supply 782698-01 (24 VDC, 5 A, 100 VAC to 120 VAC/200 VAC to 240 VAC input) What to Do Complete the following steps to connect a power supply to the cRIO-9035.
The device driver software automatically detects the cRIO-9035. If the device driver software does not detect the cRIO-9035, verify that you installed the appropriate NI software in the correct order on the host computer. You can also use the Ethernet port to connect directly to the host computer or network.
Select the Network Settings tab to configure the IP and other network settings. (Optional) Use the RJ-45 Ethernet port 1 to reconnect the cRIO-9035 to the host computer. The cRIO-9035 attempts to initiate a DHCP network connection at powerup. Note If the cRIO-9035 cannot obtain an IP address, it connects to the network with a link-local IP address with the form 169.254.
Page 16
Table 4. STATUS LED Indicators LED Pattern Indication Color Yellow Blinks twice and The cRIO-9035 is in safe mode. Software is not installed, pauses which is the factory default state, or software has been improperly installed on the cRIO-9035. An error can occur when an attempt to upgrade the software is interrupted.
NI cRIO-9035 Sync Firmware Licensing Software is licensed pursuant to the software license agreements provided with the software or, in the absence of such license agreements, the National Instruments Software License Agreement available at ni.com/legal at the time of purchase.