Sharp JW-20CM User Manual page 157

Programmable controller
Table of Contents

Advertisement

· Operation condition monitor flag [2]
This flag is used to monitor the abnormal stop of each station when the communication with each
station is normal.
Non-connected station keeps this flag as "OFF."
Flag
Own
Communication monitor flag (1) of the own station is turned "ON."
station
flag
Communication monitor flag (1) of the own station is turned "OFF."
Flag
Each station is normal.
Any of the stations is faulty (caused to be stopped
Other
abnormally).
station's
Communication monitor flag (1) of the own station
flag
is turned "OFF."
Slave station that communication monitor flag (1) is
turned to "OFF."
※ Even if a own station PC has stopped operation normally or by an error, the JW-20CM turns
"ON" this flag while communicating.
Condition for flag operation
Condition for flag operation
9
59
·
Flag operation
※ON
OFF
Flag operation
ON
Specific
station
OFF
All stations
Not specified
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jw-20rs

Table of Contents