Page 1
AUTOCHARGE:EV EV OPENCHARGE (GPRS/Ethernet Communication) INSTALLATION & OPERATION MANUAL MODELS: SINGLE PHASE OCPP0010 1 X 3.6kW OCPP0011 1 X 7.2kW OCPP0020 2 X 3.6kW OCPP0021 2 X 7.2kW 3 PHASE OCPP0012 1 X 11kW OCPP0013 1 X 22kW OCPP0022 2 X 11kW...
Page 2
Date Published: December 2021 Rolec Services Ltd are the publishers of this document and own the rights to use the text, images and all technical content contained within. Content supplied by third parties / partner organisations remains the property of that organisation and is used by agreement with the supplier.
Product Support Contents Product Support Safety Safety Advice within this Manual Product Overview Features Product Specification Physical Specification Electrical Specification Certifications and Compliances Options and Accessories Unpacking Standard Contents Labelling Information Labels Installation Before Installation Base Installation – If Supplied: If a Base is Not Supplied: Schematics Install the Charger...
Rolec Services Ltd cannot accept any responsibility for improper installation or any problems arising from improper installation. NOTE: Damage to the equipment, connected systems or to property caused by improper installation are the responsibility of the installer.
The AutoCharge:EV OpenCharge pedestal is available with the following power options: Model Number Specification OCPP0010 AutoCharge EV OpenCharge OCPP - 1x 3.6kW (16A) Type 2 socket OCPP0011 AutoCharge EV OpenCharge OCPP - 1x 7.2kW (32A) Type 2 socket OCPP0020 AutoCharge EV OpenCharge OCPP - 2x 3.6kW (16A) Type 2 sockets...
Product Specification Product Specification Physical Specification Dimensions 1275 x 323 x 270 mm (HxWxD) Material Steel Enclosure Mass < 24.5kg Operating Temperature -30°C to +50°C Operating Humidity Range 5% to 95% 332mm 270mm Instructions RFID Antenna Reader Panel Lock Socket QR Code Charging Sockets...
Options and Accessories Certifications and Compliances This product has been designed and built in accordance with the following standards and legislation: Version 1.6 J OCPP EN 61851-1:2011 Charging Compliance BS 7671 Wiring Regulations EN 301 489-01 V2.2.0, EMC Compliance EN 301 489-03 V2.1.1, EN 301 489-52 V1.1.0, EN 50470-1:2006 (1x Skt) or EN 55032:2012 (2x Skts) 2014/35/EU...
Labelling Labelling Installers must observe any/all warning labels displayed on the equipment or inside the equipment enclosure. Labels may be in the form of adhesive ‘stickers’, plates, and/or moulded into the surface of components. Information Labels Figure 2 Typical Product / Rating Label Figure 3 Typical Fascia Label Figure 4 Power Rating Label (as appropriate) Figure 5 Electricity Warning Label (as appropriate)
It is assumed that a suitable GPRS signal has already been verified by the end user/installer prior to installation. Rolec cannot be held responsible or accountable in the event a GPRS unit is installed in a location without adequate network signal.
Typically, into concrete, M8 x 100mm Anchor Bolts should be used but installers must assess the site and choose the most appropriate fastener for their needs. Schematics Applicable to single-phase, single socket units: OCPP0010 OCPP0011 Figure 8 Single Phase, Single Socket AutoCharge:EV OpenCharge – Schematic EVACOCM-01-V02-R3 Installation and Operation Manual...
Page 12
Installation Applicable to single-phase, double socket units: OCPP0020 OCPP0021 24 G LIVE NEUTRAL EARTH 24 G Figure 9 Single Phase, Double Socket AutoCharge:EV OpenCharge – Schematic AutoCharge:EV OpenCharge EVACOCM-01-V02-R3 Installation and Operation Manual Page 11 of 21 December 2021...
Page 13
Installation Applicable to three-phase, single socket units: OCPP0012 OCPP0013 Figure 10 Three Phase, Single Socket AutoCharge:EV OpenCharge – Schematic EVACOCM-01-V02-R3 Installation and Operation Manual AutoCharge:EV OpenCharge Page 12 of 21 December 2021...
Page 14
Installation Applicable to three-phase, single socket units: OCPP0022 OCPP0023 SNUBBER LIVE 1 LIVE 2 LIVE 3 NEUTRAL EARTH SNUBBER Figure 11 Three Phase, Double Socket AutoCharge:EV OpenCharge – Schematic AutoCharge:EV OpenCharge EVACOCM-01-V02-R3 Installation and Operation Manual Page 13 of 21 December 2021...
Installation Install the Charger 1. Release and remove the access panel using the supplied key. 2. Carefully lift the pedestal then lower it to fit the power cable (and ethernet cable if required) through the rubber mat and into the chassis. Fully lower the chassis onto either: the ground mounting base (align the four holes in the chassis with the four studs of the base).
Commissioning Commissioning If the VendElectric service is NOT being used, another service provider will be required to administer smart services and commissioning will need to be performed in accordance with the alternative service provider’s instructions. Commissioning with VendElectric NOTE: A Smartphone or similar web enabled device with a working internet connection is required for the next steps.
Operation Operation NOTE: At the end of a charging session, always disconnect the cable from the vehicle before disconnecting from the charger. Operating instructions for this charger are shown on the unit fascia. For more detail, refer to the EV Driver App User Guide included within the charger packaging. VendElectric EV Driver Application The VendElectric EV Driver Application is a free download for use with smartphones running Google Android or Apple IOS.
Operation To End a Charging Session 1. Use the mobile application to end the charge session. 2. Alternatively use an RFID card/fob to end the charging session. Or… The charger will issue a ‘beep’ sound to indicate the card has been recognised.
NOTE: In the event of a hardware issue, always contact your installer first. If damage has been sustained to communications devices and/or other ‘Smart’ components, it is recommended that an approved Rolec installer is called to perform the repair. Damage caused to the equipment by misuse, lack of maintenance, inappropriate maintenance or modification is not covered by the manufacturer warranty.
Maintenance Suggested Inspection and Testing A record or inspection, testing and maintenance should be kept and may be required to support any claims within the warranty period. and 3 Quarter and 4 Quarter External Visual Inspection: External Visual Inspection: Check for physical damage. Check for physical damage.
HOST’S GUIDE Getting Connected To onboard your Rolec charging points to the VendElectric system simply follow the following steps: 1. PURCHASE YOUR CHOSEN PLAN 2. BOOK YOUR INSTALLATION For each project you will need to: Contact your chosen Installer to...
VendElectric Back Office this can be done during the handover process. where they can also access easy-to- Rolec equipment is covered by a parts warranty, follow video walkthroughs of the system, however we recommend that you consider offering...
Page 24
THE UK’S LEADING MANUFACTURER OF EV CHARGING POINTS t: 01205 724773 e: enquiries@rolecserv.co.uk www.rolecserv.com...