On-screen message
Cooling Error
AmbientTempAlm07
AmbientTempAlm00
Battery Alm XX
Proc1 Vccp AlmXX
Proc2 Vccp AlmXX
BB FSBvtt Alm XX
BB DIMMvtt AlmXX
BB +1.2v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +1.2vs Alm XX
BB +1.5vs Alm XX
BB +1.25vs AlmXX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Description
In the Blade Enclosure, the number
of fans installed is insufficient or the
installed fan is faulty. Thus, the CPU
blade failed to power on due to
insufficient cooling power.
A high temperature warning was
detected in chassis.
A low temperature warning was
detected in chassis.
A battery voltage warning was
detected.
XX=07: Upper limit warning
XX=00: Lower limit warning
A voltage warning was detected.
XX=07: Upper limit warning
XX=00: Lower limit warning
General Description 2-13
Action
Check if fans in Blade Enclosure
work normally.
Refer to the User's Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and CPU blades
are installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
1. Check installation status of
battery.
2. Replace the battery.
Replace the CPU blade.