2.2

Restrictions

This section describes the restrictions when the QA1S6ADP-S1 is used.
Applicable CPU modules
The following CPU modules support the connection with the QA1S6ADP-S1+A1S5B/
A1S6B.
• High Performance model QCPU
• Universal model QCPU with a serial number (first five digits) of "13102" or later
Base unit connection
• Connect the extension base units to the main base unit in order of Q5B/Q6B and
QA1S6ADP-S1+A1S5B/A1S6
QA6B, QA1S5B, QA1S6B, or QA6ADP+A5B/A6B in the system.
• Set the extension levels of the QA1S6ADP-S1s to 1 to 3 in order connected.
• Set the same level to the extension level setting connectors of the QA1S6ADP-S1 and the
extension base unit.
• When the QA1S6ADP-S1+A1S5B/A1S6B is used, the number of extension base units is
limited to three including the number of Q series extension base units.
Software
• The number of slots of the QA1S6ADP-S1+A1S5B/A1S6B is always displayed as eight in
GX Works2 or GX Developer, regardless of the actual number of slots of the extension base
unit where the QA1S6ADP-S1 is mounted.
• Batch assign I/O numbers to the modules by the series, in order of "Q seriesAnS series" or
"AnS seriesQ series". If not, an error (SP.UNITLAY ERR) occurs. Assign I/O numbers so
that they do not overlap.
Restricted functions
The QA1S6ADP-S1+A1S5B/A1S6B cannot be connected to a MELSECNET/H remote I/O
station.
The QA1S6ADP-S1+A1S5B/A1S6B cannot be bus-connected with GOT.
B. The QA1S6ADP-S1 cannot be used together with the
9