3 Installation and commissioning
3.5.5 Connecting power supply to and grounding the controller
Continued
Required equipment
Equipment
External earth fault protection (residual current device,
RCD)
Standard toolkit
Circuit diagram
Line fusing
There is no integrated fuse inside the OmniCore E10 controller. An external fuse
or circuit breaker must be added by the integrator, according to the full load current
rating. See
Connecting the power
The following procedure describes how to connect the main power to the controller.
1
74
Load current on page
CAUTION
Always inspect the connector for dirt or damage before connecting it to the
controller. Clean or replace any damaged parts.
Action
Connect the main power cable to the power inlet connector X0 and lock it by
pressing the locking levers.
Tip
When you hear a clear clicking sound, it is locked.
© Copyright 2019-2022 ABB. All rights reserved.
Note
30, Type B (ABB F202 B-16/0.03
or equal residual current circuit
breaker.)
See
Standard toolkit for controller
on page
Circuit diagram - OmniCore E10,
3HAC076810-008
38.
Product manual - OmniCore E10
202.
3HAC079399-001 Revision: C