3.
NOTE
NOTE
4.
5.
C Series Maintenance Manual Rev.2
Install the base cover to the Manipulator.
Hexagon socket head cap bolts: 11-M4×10
Tightening torque: 4.0 ± 0.2 N·m
Be careful not to get the gasket and cables caught between
the cover and the Manipulator.
Replace the gasket if there are flaws or deteriorations.
For cleanroom and protection models, install the gasket
between the heat sink and the base cover.
Install the heat sink.
Hexagon socket head cap bolts: 4-M4×15
Tightening torque: 4.0 ± 0.2 N·m
Install the fan.
For details, refer to C8 Maintenance 15. Replacing the Fan.
C8 Maintenance 3. Covers
215