Example: Upright Position; Degree Of Protection; Acs880-01, Acs580-01, Acsh580-01 And Acq580-01; Acs880-11, Acs880-31, Ach580-31 And Acx580-31 - ABB ACS880-01 Installation Manual

Flange mounting kit
Hide thumbs Also See for ACS880-01:
Table of Contents

Advertisement

Example: upright position

4
5
6
4

Degree of protection

ACS880-01, ACS580-01, ACSH580-01 and ACQ580-01

The degree of protection of a flange-mounted IP21 drive is IP20 on the front side and
IP55 on the backside. The degree of protection of a flange-mounted IP55 drive is
IP55 on both the front side and the backside.

ACS880-11, ACS880-31, ACH580-31 and ACX580-31

The degree of protection of a flange-mounted IP20 drive is IP20 on the front side and
IP55 on the backside. The degree of protection of a flange-mounted IP21 drive is
IP21 on the front side and IP55 on the backside. The degree of protection of a flange-
mounted IP55 drive is IP55 on both the front side and the backside.
1
2
3
8
Hardware description 15
1
Hood (in the cooling air
channel; required for UL
4
type 12)
2
Top flange bracket
3
Mounting plate
4
Lifting hole
5
Drive heat sink in the cooling
air channel
6
Side flange bracket
7
7
Drive front side
8
Bottom flange bracket
4

Advertisement