Foreword

Thank you for purchasing the TOPCON GREEN LABEL Auto Level AT-G Series.
For the best performance of the instruments, please read these instructions
carefully and keep them in a convenient location for future reference.
General Handling Precautions
• Before starting work or operation, be sure to check that the instrument
is functioning correctly with normal performance.
Display for safe use
In order to encourage the safe use of products and prevent any danger to the
operator and others or damage to properties, important warnings are put on the
products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays and
icons before reading the "Safety Cautions" and text.
Display
WARNING
CAUTION
1) Injury refers to hurt, burn, electric shock, etc.
2) Physical damage refers to extensive damage to buildings or equipment
and furniture.
Safety Cautions
• Cause eye injury or blindness.
Do not look at the sun through a telescope.
It is suggested to pay care specially at the time the position of the sun is
low such in the morning or evening, or at the time the sunlight is coming
directly to the objective lens of the instrument, cut off the sunlight by your
hand or use an umbrella in such case.
• Do not use the staff in conditions of thunder and lightening.
As this is an electric conductor, thunderbolt can cause serious injury or
death.
• Keep the staff away from electric facilities such as a high voltage
wire or substation.
As this is an electric conductor, there is danger of electric shock.
Risk of injury by overturn the carrying case.
Do not stand or sit on the carrying cases.
Please note that the tips of tripod can be hazardous, be aware of this
when setting up or carrying the tripod.
Risk of injury by falling down the instrument or case.
Do not use a carrying case with a damaged which belts, grips or latches.
A plumb bob can cause an injury to a person if used incorrectly.
Ensure that you mount the Tribrach correctly, failing to do so may result in
injury if the tribrach were to fall over.
It could be dangerous if the instrument falls over, please check that you
fix the instrument to the tripod correctly.
Risk of injury by falling down a tripod and an instrument.
Always check that the screws of tripod are tightened.
User
1) This product is for professional use only!
The user is required to be a qualified surveyor or have a good knowledge of surveying,
in order to understand the user and safety instructions, before operating, inspecting or
adjusting.
2) Wear the required protectors (safety shoes, helmet, etc.) when operating.
Exceptions from Responsibility
1) The user of this product is expected to follow all operating instructions and make
periodic checks of the product's performance.
2) The manufacturer, or its representatives, assumes no responsibility for results of a
faulty or intentional usage or misuse including any direct, indirect, consequential
damage, and loss of profits.
3) The manufacturer, or its representatives, assumes no responsibility for consequential
damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.).
A fire, accident, or an act of a third party and/or a usage any other usual conditions.
4) The manufacturer, or its representatives, assumes no responsibility for any damage,
and loss of profits due to a change of data, loss of data, an interruption of business etc.,
caused by using the product or an unusable product.
5) The manufacturer, or its representatives, assumes no responsibility for any damage,
and loss of profits caused by usage except for explained in the user manual.
6) The manufacturer, or its representatives, assumes no responsibility for damage caused
by wrong movement, or action due to connecting with other products.
Standard set component
Model AT-G4 or AT-G6 ............................ 1each
Plastic carrying case ................................ 1each
Lens cap .................................................. 1each
Plumb bob set........................................... 1each
Hexagonal wrench.................................... 1each
Silicon cloth .............................................. 1each
Vinyl cover ................................................ 1each
Instruction manual .................................... 1each

Specifications

Telescope
Overall length ............................................. 192mm(AT-G4)
Image ......................................................... Erect
Effective diameter lens ............................... 30mm
Magnification .............................................. 26X(AT-G4)
Field of view ............................................... 1°30'
Resolving power ......................................... 3.5"(AT-G4)
Minimum focus ........................................... 0.5m
Horizontal circle
Diameter ..................................................... 117mm
Minimum reading ........................................ 1°
Automatic compensation mechanism
.............................................. ±
Range
Measuring accuracy
1 km double run
Circular level
Sensitivity ................................................... 8'/2mm
Other
Protection against water and dust .............. IPX7
(Based on the standard IEC60529)
Weight
Instrument .................................................. 1.6kg
Plastic carrying case .................................. 1.3kg
Nomenclature
Focusing knob
Horizontal knob
Operating
Setting
1
First position the tripod leg and then
spread the other two so as to make
the tripod head almost level.
2
Firmly position the tripod legs on the
ground, then tighten the screws.
3
Place the instrument on the tripod
head, then screw the tripod screw
into the instrument bottom for secur-
ing it to the tripod.
4
Use a plumb bob to match the instru-
ment center with the measuring point
when a horizontal scale is used.
5
Use the three leveling screws to cen-
ter the circular level. When a dome
head tripod is used loosen the tripod
screw a little, slide the instrument,
center the bubble, looking at the
level, then the tripod screw to secure
the instrument.
Collimating
1
Direct the telescope to bright object
and turn the eyepiece ring so that the
reticle in the telescope is clearly seen.
2
Turn the instrument manually and
align the target through the sighting
collimator.
3
Focus the target with the focusing
knob.
4
Turn the horizontal knob to match the
reticle with the target.
Measuring (Height)
• In order to measure the difference in height
between point A and point B.
1
Set up the instrument almost in the
middle of the points.
2
Provide a leveling rod at point A and
B, one each, collimate them and read
the horizontal line of the reticle.
3
Suppose the reading at point A is a
and that at point B id b, and the differ-
ence in height between the two points
will be: a - b
Ignoring or disregard of this display may lead to death or
serious injury.
Ignoring or disregard of this display may lead to personal
injury or physical damage to the instrument.
.................................. ±
Circular level viewing prism
Objective lens
Leveling screw
INSTRUCTION MANUAL
AUTO LEVEL
Meaning
WARNING
CAUTION
193mm(AT-G6)
24X(AT-G6)
4"(AT-G6)
15'
2.0mm
Sighting collimator
Circular level
Horizontal circle
Leveling
screw
Fixing
screw
Leg
AT-G4
AT-G6
Eyepiece
Tripod head
Tripod
screw
Adjuster
Plumb bob
Measuring point
Circular level
Target
Collimator
Base plate

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT-G4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Topcon AT-G4

  • Page 1 AT-G4 AT-G6 Foreword Thank you for purchasing the TOPCON GREEN LABEL Auto Level AT-G Series. For the best performance of the instruments, please read these instructions carefully and keep them in a convenient location for future reference. General Handling Precautions •...
  • Page 2 Phone: 031-7109200 Fax: 031-7109249 TOPCON CORPORATION BEIRUT OFFICE TOPCON (GREAT BRITAIN)LTD. P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K. Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119 TOPCON CORPORATION DUBAI OFFICE Phone: 44-1635-551120 Fax: 44-1635-551170 survey.sales@topcon.co.uk laser.sales@topcon.co.uk...

This manual is also suitable for:

At-g6

Table of Contents