GE Kelman Minitrans Installation Manual page 59

Transformer oil dissolved gas and moisture monitor
Hide thumbs Also See for Kelman Minitrans:
Table of Contents

Advertisement

Note:
GE recommends the use of grade A2 stainless steel bolts (supplied as part of
the installation kit - KAN01056) to connect the support bracket to the
transformer.
Place the support bracket (21-1318) at the mounting position on the transformer and
bolt in position with the fittings as shown in Figure L-9 (recommended torque is 12
Nm).
M6 bolt (20, 40 or 60 mm as
required) and M6 flat
washer
Figure L-9: Fitting the support bracket
Insert the four isolators (MECH09025) onto the threaded inserts and tighten by hand as
shown in Figure L-10.
Isolators
screwed
into
threaded
inserts
Figure L-10: Support bracket with top isolators fitted
MA-005 - Minitrans Installation Manual - Rev 4.5
404 mm (± 2 mm)
Mounting slots
M6 nut, M6 spring & M6
washer
Use the same fittings for all four holes.
Figure L-11: Mounting slot
dimensions
548.5 mm
(± 1 mm)
Note:
3.5 mm
5 mm
13-Aug-20
Page 59 of 86