Standard specifications

Standard specifications
 Rating (Standard model)
 200 V class
Model FR-A820-[ ]-R2R
SLD
Applicable
LD
motor
SND

capacity
ND
2
(kW)

(initial setting)
HD
SLD
LD
Rated
SND

capacity
ND
(kVA)

(initial setting)
HD
SLD
LD
Rated
SND

current
ND
(A)
(initial setting)
HD
SLD
LD
Overloa
SND

d current
ND
rating

(initial setting)
HD
Rated voltage

Brake transistor Built-in
Maximum
Regener
brake torque
ative
FR-ABR
braking
(when the
option is
used)
Rated input
AC voltage/frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
SLD
LD
Rated
input
SND

current
ND
(A)

(initial setting)
HD
SLD
LD
Power
supply
SND

capacity
ND
(kVA)

(initial setting)
HD
Protective structure
(IEC 60529)

Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

For the SND rating, the carrier frequency is always 2 kHz.

The 0.2 kW motor capacity is applicable under V/F control only.

The rated output capacity indicated assumes that the output voltage is 220 V for 200 V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the
maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

Value for the built-in brake resistor

Value for the ND rating

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables)
affects the rated input current.
22

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input
reactor and cables).

FR-DU08: IP40 (except for the PU connector section)
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.4K 0.75K 1.5K
2.2K
3.7K
0.75
1.5
2.2
3.7
5.5
0.75
1.5
2.2
3.7
5.5
0.75
1.5
2.2
3.7
5.5
0.4
0.75
1.5
2.2
3.7
0.2
0.4
0.75
1.5
2.2

1.8
2.9
4
6.4
10
1.6
2.7
3.7
5.8
8.8
1.6
2.7
3.7
5.8
8.8
1.1
1.9
3
4.2
6.7
0.6
1.1
1.9
3
4.2
4.6
7.7
10.5
16.7
25
4.2
7
9.6
15.2
23
4.2
7
9.6
15.2
23
3
5
8
11
17.5
1.5
3
5
8
11
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
150% 60 s (inverse-time characteristics) at surrounding air temperature of 50°C
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Three-phase 200 to 240 V
150% torque/3%ED
100% torque/
3%ED



150% torque/
100% torque/10%ED
10%ED
Three-phase 200 to 240 V 50 Hz/60 Hz
170 to 264 V 50 Hz/60 Hz
±5%
5.3
8.9
13.2
19.7
31.3
5
8.3
12.2
18.3
28.5
5
8.3
12.2
18.3
28.5
3.9
6.3
10.6
14.1
22.6
2.3
3.9
6.3
10.6
14.1
2
3.4
5
7.5
12
1.9
3.2
4.7
7
11
1.9
3.2
4.7
7
11
1.5
2.4
4
5.4
8.6
0.9
1.5
2.4
4
5.4
Enclose type (IP20)
Self-cooling
Forced air cooling
2.0
2.2
3.3
3.3
3.3
5.5K
7.5K
11K
15K 18.5K 22K
7.5
11
15
18.5
22
30
7.5
11
15
18.5
22
30
7.5
7.5
15
18.5
22
22
5.5
7.5
11
15
18.5
22
3.7
5.5
7.5
11
15
18.5
13
19
24
29
35
48
12
17
22
27
32
43
12
14
22
27
32
39
9.1
13
18
23
29
34
6.7
9.1
13
18
23
29
34
49
63
77
93
125
31
45
58
70.5
85
114
31
36
58
70.5
85
102
24
33
46
61
76
90
17.5
24
33
46
61
76
100% torque/
20% torque/continuous
2%ED

100% torque/6%ED
45.1
62.8
80.6
96.7
115
151
41.6
58.2
74.8
90.9
106
139
41.6
49
74.8
90.9
106
130
33.4
44.2
60.9
80
96.3
113
22.6
33.4
44.2
60.9
80
96.3
17
24
31
37
44
58
16
22
29
35
41
53
16
19
29
35
41
50
13
17
23
30
37
43
8.6
13
17
23
30
37
6.7
6.7
8.3
15
15
15
30K
37K
45K
55K
75K
90/
37
45
55
75
132
110
37
45
55
75
90
110
30
45
45
55
90
90
30
37
45
55
75
90
22
30
37
45
55
75
59
71
89
120
145
181
53
65
81
110
132
165
48
65
72
99
132
148
44
55
67
82
110
132
34
44
55
67
82
110
154
187
233
316
380
475
140
170
212
288
346
432
126
170
190
259
346
388
115
145
175
215
288
346
90
115
145
175
215
288
FR-BU2 (Option)
10% torque/
continuous
185
221
269
316
380
475
178
207
255
288
346
432
166
207
233
304
346
388
150
181
216
266
288
346
113
150
181
216
215
288
70
84
103
120
145
181
68
79
97
110
132
165
63
79
89
116
132
148
57
69
82
101
110
132
43
57
69
82
82
110
Open type (IP00)
22
42
42
54
74
74
.
90K

Advertisement

loading

This manual is also suitable for:

Fr-a800 plus