Features
Parameters can be used for mechanical adjustment according to applications, useful for the startup and adjustment work
of the system.
1
Setting and adjusting multiple devices including
controllers were required for dancer control, and it
took much time to start up the system.
• Complex position control of the dancer roll can be achieved by the inverter alone by setting parameters.
• By setting mechanical specifications, optimum control can be performed according to the system and the application.
• Analog/pulse signal input method is selectable at the discretion of the customer. Input via communication is also
available.
• PID control enables and simplifies complex control using only the inverter.
• Automatic tension PI gain adjustment enables easy startup. (Tension PI gain tuning)
14
Easy startup and adjustment
Before
There was a worry about the compatibility with the
existing system.
After
Before