Download Print this page

Mitsubishi Electric 800 Plus Series Manual page 17

Hide thumbs Also See for 800 Plus Series:

Advertisement

Inverter by rating
• 200 V class
SLD (Super light duty)
Inverter model
Motor capacity
Rated current
FR-A820-
(kW)*
1
0.4K
00046
0.75
0.75K
00077
1.5
1.5K
00105
2.2
10.5
2.2K
00167
3.7
16.7
3.7K
00250
5.5
5.5K
00340
7.5
7.5K
00490
11
11K
00630
15
15K
00770
18.5
18.5K
00930
22
22K
01250
30
30K
01540
37
37K
01870
45
45K
02330
55
55K
03160
75
75K
03800
90/110
90K
04750
132
• 400 V class
SLD (Super light duty)
Inverter model
Motor capacity
Rated current
FR-A84-
(kW)*
1
0.4K
00023
0.75
0.75K
00038
1.5
1.5K
00052
2.2
2.2K
00083
3.7
3.7K
00126
5.5
12.6
5.5K
00170
7.5
7.5K
00250
11
11K
00310
15
15K
00380
18.5
18.5K
00470
22
22K
00620
30
37
30K
00770
37K
00930
45
45K
01160
55
55K
01800
75/90
75K
02160
110
90K
02600
132
110K
03250
160
132K
03610
185
160K
04320
220
185K
04810
250
220K
05470
280
250K
06100
315
280K
06830
355
315K
07700
400
355K
08660
450
500
400K
09620
450K
10940
560
1094
500K
12120
630
1212
Overload current rating
SLD
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
LD
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
SND
150% 60s (inverse-time characteristics) at surrounding air temperature of 50°C
ND
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
HD
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
*1: The applicable motor capacity is the maximum applicable capacity of a Mitsubishi 4-pole standard motor.
LD (Light duty)
SND (Super normal duty)
Motor capacity
Rated current
Motor capacity
(A)
(kW)*
(A)
1
4.6
0.75
4.2
7.7
1.5
7
2.2
9.6
3.7
15.2
25
5.5
23
31
34
7.5
49
11
45
63
15
58
77
18.5
70.5
93
22
85
125
30
114
154
37
140
187
45
170
212
233
55
316
75
288
380
90
346
475
110
432
LD (Light duty)
SND (Super normal duty)
Motor capacity
Rated current
Motor capacity
(A)
(kW)*
1
(A)
2.3
0.75
2.1
3.8
1.5
3.5
5.2
2.2
4.8
7.6
8.3
3.7
5.5
11.5
17
7.5
16
25
11
23
31
15
29
38
18.5
35
47
22
43
62
30
57
70
77
37
93
45
85
116
55
106
180
75
144
216
90
180
260
110
216
325
132
260
325
361
160
432
185
361
481
220
432
547
250
481
610
280
547
683
315
610
770
355
683
866
400
770
962
450
866
500
962
560
1094
ND (Normal duty initial value)
Rated current
Motor capacity
(kW)*
(A)
(kW)*
1
1
0.75
4.2
0.4
1.5
7
0.75
2.2
9.6
1.5
3.7
15.2
2.2
5.5
23
3.7
7.5
31
5.5
7.5
36
7.5
15
58
11
18.5
70.5
15
22
85
18.5
102
22
22
30
126
30
45
170
37
45
190
45
55
259
55
90
346
75
90
388
90
ND (Normal duty initial value)
Rated current
Motor capacity
(kW)*
1
(A)
(kW)*
1
0.75
2.1
0.4
1.5
3.5
0.75
2.2
4.8
1.5
3.7
7.6
2.2
5.5
11.5
3.7
7.5
16
5.5
11
23
7.5
15
29
11
18.5
35
15
22
43
18.5
30
57
22
30
37
70
45
85
37
55
106
45
55
129
55
90
180
75
90
194
90
132
260
110
160
325
132
185
361
160
220
432
185
250
481
220
280
547
250
315
610
280
355
683
315
400
770
355
400
450
866
500
962
450
560
1094
500
Features
HD (Heavy duty)
Rated current
Motor capacity
Rated current
(A)
(kW)*
(A)
1
3
0.2
1.5
5
0.4
3
8
0.75
5
11
1.5
8
17.5
2.2
11
24
3.7
17.5
33
5.5
24
46
7.5
33
61
11
46
76
15
61
90
18.5
76
90
115
22
145
30
115
175
37
145
215
45
175
288
55
215
346
75
288
HD (Heavy duty)
Rated current
Motor capacity
Rated current
(A)
(kW)*
1
(A)
1.5
0.2
0.8
2.5
0.4
1.5
4
0.75
2.5
6
1.5
4
9
2.2
6
12
3.7
9
17
5.5
12
23
7.5
17
31
11
23
38
15
31
44
18.5
38
57
22
44
71
30
57
86
37
71
110
45
86
144
55
110
180
75
144
216
90
180
260
110
216
325
132
260
361
160
325
432
185
361
481
220
432
547
250
481
610
280
547
683
315
610
770
355
683
866
400
770
962
450
866
1
17

Advertisement

loading

This manual is also suitable for:

Fr-a800 plus