GENERAL SPECIFICATIONS AND PRECAUTIONS FOR USE

1.2.3 I/O combined module

1 - 14
(1) I/O numbers of I/O combined modules
There are two types of I/O combined modules:
• Module using same I/O numbers for input and output
Since same number is used for input and output, the I/O numbers to be
used can be saved.
• Module using sequential I/O numbers for input and output
Since I/O assignments are the same for A series, it is useful when replacing
modules from those of A series.
Input (X)
Output (Y)
00
X00
Y00
1F
X1F
Y1F
Module using same I/O numbers for input
and output (QH42P)
(2) Configuration of when an I/O combined module is used
For the QH42P, QX41Y41P, and QX48Y57, use them in the configuration below.
Product
CPU module
GX Developer
For how to check the serial number of the CPU module, refer to the QCPU User's
Manual (Hardware Design, Maintenance and Inspection).
00
32 points
1F
20
3F
Module using sequential I/O numbers for input
Description
The module whose serial number
(first 5 digits) is "01112" or later
SW4D5C-GPPW or earlier
SW5D5C-GPPW or later
MELSEC-Q
Input (X)
Output (Y)
X00
Vacant
X1F
Y20
Vacant
Y3F
and output (QX41Y41P)
Precautions
-
• Use it with "Output" being set to
the I/O assignment.
• Input response time cannot be
set. (fixed at 10ms)
Use it with "I/O combined" being
set to the I/O assignment.
32 points
32 points