Installation and Setup
DANGER!
Subsequent to the initial installation, when any of the above optical cleaning procedures are performed,
it is recommended that power be removed from the GX2-EA1000C*/* transmitter for your protection.
Installing the GX2-EA1000C*/* in the GX2-HSG*
You are now ready to insert the GX2-EA1000C*/* into the GX2-HSG*. All slots in the
GX2-HSG* are universal and intended for the Omnistar GX2 application modules, except
the narrow, right-most slot, which is reserved for the control module. All GX2 application
modules can be installed or removed in a powered-on or powered-off GX2-HSG*.
To insert and power-up the GX2-EA1000C*/*in the GX2-HSG*:
1. Slide the GX2-EA1000C*/* fully into the designated shelf slot that contains the
previously installed G- to F-type connectors mounted on the GX2-HSG*.
2. Ensure that a firm connection is achieved with the GX2-HSG* backplane. Power is
automatically applied when contact is made with the backplane connectors.
3. Tighten the thumbscrew at the bottom of the GX2-EA1000C*/* to secure it in the
GX2-HSG* slot. You can tighten the thumbscrew firmly with your fingers or torque
to 7 ±3 in-lb.
GX2 EA1000C*/* Multi-Wavelength DWDM 1550 nm Laser Transmitter • User Guide
589569-001-a
Figure 12: Typical GX2-HSG* Configuration
B