Original installation and operation manual
Illustration
t = 30 ms
n = 20
t = 30 ms
t = 30 ms
t = 40 ms (BM12)
t = 140 ms (BM13)
t = 500 ms
For further information about fault indications during operation see "15. Troubleshooting / FAQ" on Page 55.
n = 2
t = 500 ms
n = ∞
t = 30 ms
t = 970 ms
Fail-Safe
t = 500 ms
n = ∞
BEKOMAT
Description / explanation
Positive power-on self-test (repeat 2x)
•
The red Alarm LED is off
•
The green Valve LED lights up during the solenoid
valve cycles
•
The green Power LED is on
•
The solenoid valve cycles
0 goes into normal operation
Negative power-on self-test (repeat 20x)
•
The red Alarm LED is on
•
The green Valve LED lights up during the solenoid
valve cycles
•
The green Power LED is on
•
The solenoid valve cycles
0 Goes to fail-safe operation (continuous loop)
•
The solenoid valve cycles once per second
Ready for operation (normal operating mode)
•
The red Alarm LED is off
•
The green Valve LED is off
•
The green Power LED is on
Discharge procedure
(TEST button pressed briefly)
•
The red Alarm LED is off
•
The green Valve LED lights up during the discharge
procedure
•
The green Power LED is on
Pre-alarm (
TEST button pressed >1 min and <5 min
•
The red Alarm LED flashes
•
The green Valve LED is on
•
The green Power LED is on
Alarm
(TEST button pressed >5 min)
•
The red Alarm LED is on
•
The green Valve LED is off
•
The green Power LED is on
Alarm mode (problem with condensate discharge)
•
The red Alarm LED flashes
•
The green Power LED lights up
•
The green Valve LED lights up during the solenoid
valve cycles
•
The solenoid valve sets a cycle every 4 minutes
0 Passes to normal mode with free condensate discharge
12, 12 CO, 12 CO PN63
®
)
35 | 64