Pmfy-P20Vbm-E#2 Pmfy-P20Vbm-Er3 - Mitsubishi Electric City Multi PMFY Series Technical & Service Manual

Split-type, heat pump air conditioners, ceiling cassettes
Table of Contents

Advertisement

PMFY-P20VBM-E#2
PMFY-P20VBM-ER3
TO OUTDOOR UNIT
TO MA-REMOTE
BC CONTROLLER
CONTROLLER
REMOTE CONTROLLER
DC8.7-13V
DC24-30V
TB15
M1 M2
1
2
M
MV
*See fig : W1
SW2
MODELS
ON
ON
P20VBM
OFF
OFF
123456
1234567
ON
ON
P25VBM
OFF
OFF
123456
1234567
ON
ON
P32VBM
OFF
OFF
123456
123456
ON
ON
P40VBM
OFF
OFF
123456
123456
The black square (
) indicates a switch position.
LED on indoor board for service
Mark
Meaning
Main power supply (Indoor unit:220-240V)
Main power supply
LED1
Power on → Iamp is lit
Power supply for
Power supply for MA-Remote controller
LED2
MA-Remote controller
on → Iamp is lit
[LEGEND]
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CN25
CONNECTOR HUMIDIFIER
CN27
DAMPER
CN32
REMOTE SWITCH
CN51
CENTRALLY CONTROL
CN52
REMOTE INDICATION
SW2
SWITCH
CAPACITY CORD
SW3
MODE SELECTION
SW4
MODEL SELECTOR
(
SWE
)
DRAIN UP MACHINE
TEST MODE
ZNR
VARISTOR
(
)
FUSE FUSE
T6.3AL 250V
X1
AUX.RELAY
DRAIN PUMP
(
)
LED1 POWER SUPPLY
I.B
(
)
LED2 POWER SUPPLY
I.B
MF
FAN MOTOR
MV
VANE MOTOR
DP
DRAIN PUMP
OC307F
PMFY-P25VBM-E#2
PMFY-P25VBM-ER3
FUSE
BREAKER
PULL BOX
(
15A
)
TO NEXT
INDOOR
UNIT
TB5
S
L
N
TB2
(SHIELD)
BLK
CND
(
BLK
1
3
5
FUSE
DSA
U
ZNR02
U
8 6 4 2
2 1
CNMF2
(
WHT
)
7
5
3
1
MF
MS
5
3~
BLU
CN2M
1
BLU
BLU
(
)
2
M-NET
LED2
ORN
CN3A
1
BLU
(
)
ORN
3
REMOCON
4
CN42
CN6V1
RED
(
)
GRN
(
)
ADDRESS
1
VANE
5
BRN
1
RED
1
3
CN32
ORN
REMOTE SWITCH
YLW
GRN
SW2
6
1 2 3 4 5 6
1 2 3 4 5 6 7 8 910
<
W
1>
SW3
8
9
10
A.B
SW5
8
9
10
220V
SW1
7
8
9
10
7
8
9
10
1 2 3 4 5 6 7 8 910
SW12
Function
10ths
DIGIT
SYMBOL
NAME
DS
DRAIN SENSOR
TB2
TERMINAL
POWER SUPPLY
TB5
TRANSMISSION
BLOCK
TB15
MA-REMOTE CONTROLLER
TH21
THERMISTOR ROOM TEMP. DETECTION
(
)
0°C/15kΩ, 25°C/5.4kΩ
TH22
PIPE TEMP. DETECTION / LIQUID
(
)
0°C/15kΩ, 25°C/5.4kΩ
TH23
PIPE TEMP. DETECTION / GAS
(
)
0°C/15kΩ, 25°C/5.4kΩ
LEV
LINEAR EXPANSION VALVE
A.B
CIRCUIT BOARD
SW1
SWITCH
MODE SELECTION
SW5
VOLTAGE SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10ths DIGIT
SW14
BRANCH No.
PMFY-P32VBM-E#2
PMFY-P32VBM-ER3
(
15A
)
POWER SUPPLY
~
/ N
220-240V 50Hz
220V 60Hz
)
1
3
DC311
CNP
~
ZNR01
339V
YLW
(
)
D.U.M
X1
CNMF1
WHT
(
)
CN20
(
INTAKE
CN25
SWE
4
CN41
ON OFF
(
WHT
)
HA
1
CN51
(
WHT
CENTRALLY
WHT
(
)
CONTROL
ADDRESS
SW3
SW4
CN81
RED
(
)
1
8
INDICATION
1 2 3 4 5
4
4
(RED)
240V
ADDRESS
CN43
8
1
(RED)
ADDRESS
SW11
SW14
SWC
CN82
2
1
1s
BRANCH
1
DIGIT
No.
NOTES:
1.At servicing for outdoor unit,always follow the wiring diagram of outdoor unit.
2.In case of using MA-Remote controller, please connect to TB15.
(Remote controller wire is non-polar.)
3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4.Symbol
S
of TB5 is the shield wire connection.
[
]
5.Symbols used in wiring diagram above are,
: terminal block,
6.The setting of the SW2 dip switches differs in the capacity. For the detail, refer to the table below.
7.Please set the switch SW5 according to the power supply voltage.
Set SW5 to 240V side when the power supply is 230 and 240 volts.
When the power supply is 220 volts, set SW5 to 220V side.
19
PMFY-P40VBM-E#2
PMFY-P40VBM-ER3
I.B
BLU
M
1~
BLU
DP
LED1
CN31
DS
3
(
WHT
)
DRAIN
1
BRN
6
RED
CN60
BLU
M
WHT
ORN
(
)
LEV
YLW
LEV
WHT
1
2
RED
)
TH21
1
4
TH23
2
TH22
1
(
WHT
)
1
CN44
2
(
WHT
)
1
LIQUID
CN27
/GAS
(
RED
)
1
5
)
5
CN52
GRN
(
)
REMOTE
1
8
:connecter.