Philips BVP528 Manual

Philips BVP528 Manual

Optivision led gen3.5

Advertisement

OptiVision LED gen3.5
BVP528/BVP518
1
RG1
Performance is not guaranteed for rated NOMINAL mains voltage of below 220Vac and over 400Vac.
Tolerance for voltage fluctuations: safety ±10%, performance -8/+6%, is part of the design and as per standard EN 62384.
OPERATING
TEMPERATURE
OUTDOOR
INDOOR
Configuration
BVP518 HGB
BVP518 HGB+ EXTERNAL LOUVER
BVP518 BV
BVP518 BV+EXTERNAL LOUVER
BVP528 BV
BVP528 BV+EXTERNAL LOUVER
BVP528 HGB
BVP528 HGB+EXTERNAL LOUVER
*Lumen maintenance at median useful life 50Khrs is L80
443000021241_A
© 07/2020 Signify Holding. All rights reserved
MAX.
MIN.
45ºC
-40ºC
45ºC
-40ºC
0,18
0,23
0,10
0,13
0,12
0,14
0,20
0,23
Any modification on the luminaire will cancel the warranty
BVP528 HGB
BVP528 BV
HGB
BVP528
33
BVP518
29
SCx
15º
30º
40º
0,22
0,25
0,27
0,25
0,27
0,26
0,17
0,21
0,24
0,18
0,22
0,25
0,20
0,29
0,33
0,24
0,29
0,31
0,27
0,30
0,32
0,30
0,32
0,32
1/24
BVP518 HGB
BVP518 BV
220 V
400 V
BV
90º HGB
26,5
0,47
22
0,33
50º
65º
90º
0,27
0,29
0,33
0,25
0,25
0,32
0,26
0,30
0,34
0,25
0,26
0,32
0,33
0,41
0,48
0,34
0,38
0,44
0,33
0,41
0,47
0,34
0,39
0,44
Printed in Spain
Data subject to change without notice
Keep for future reference: www.philips.com/lighting

Advertisement

Table of Contents
loading

Summary of Contents for Philips BVP528

  • Page 1 Any modification on the luminaire will cancel the warranty *Lumen maintenance at median useful life 50Khrs is L80 Printed in Spain 443000021241_A Data subject to change without notice 1/24 © 07/2020 Signify Holding. All rights reserved Keep for future reference: www.philips.com/lighting...
  • Page 2 BVP528 50000h 203000 1500 20ºC BVP518 50000h 135000 1000 20ºC BVP528 50000h 203000 1500 20ºC BVP518 50000h 135000 1000 20ºC BVP528 50000h 189000 1500 20ºC BVP518 50000h 126000 1000 20ºC BVP528 50000h 202000 1500 25ºC BVP518 50000h 134000 1000 25ºC...
  • Page 3 POSITIONS ALLOWED 80º 80º POSITIONS NOT ALLOWED NOT ALLOWED LIGHT FACING UP In luminaire version for swimming pool applications (SWP): Fixture mounting system (including fasteners) needs to be compliant with EN 13451-1 or MIS 1203 Mounting system and product shall be a subject of periodical inspection at least every year.
  • Page 4 2XM20 SCREW 1XM20 SCREW 92,5mm FLAT WASHER NEEDED In case of using only one fixation point ACCORDING TO 30mm and if the luminaire is higher >3m, the DIN9021 use of a 2nd fixing security system is needed A cable can be used as second security system. Section has to be enough for the installation and support environmental conditions (e.g.
  • Page 5 CLEANING 1. Remove physical elements that can block and modify the aircooling (heatsink fins) 2. Cleaning Frequency (depending on installa- tion place and environment) Pollution Category Cleaning Interval (months) High Medium 0,91 0,92 0,93 0,90 0,91 0,92 0,88 0,89 0,91 0,85 0,88 0,83...
  • Page 6 Always align the direc- tion TOP and BOTTOM 12NC: 912300024868 ZVP418 EXTERNAL LOUVER when installing the louver 12x screws to be removed 12x screws PRECISION AIMING DEVICE 12NC: 912300024470 AIMING DEVICE WITHOUT VISOR TURN TO CORRECT POSITION BVP528 BVP518 6/24...
  • Page 7 CHANGE FROM BV TO HGB 912300024570 A AVOV G3 RAW DRV SUPPORT V2 AND CABLE 12NC 912300024571 A AVOV G3 LGR DRV SUPPORT V2 AND CABLE GEN 3 BRACKET 912300024572 A AVOV G3 DGR DRV SUPPORT V2 AND CABLE COMPONENT TORQUE TOOL SCREW M5 (4X)
  • Page 8 EVP500 OptiVision LED gen3.5 Driver box EVP500 220 V 400 V Driver box Features Iin (Mains 220V-240V) Iin (Mains 380V-400V) 4.6A * A surge protection device should be integrated in the installation Inrush (220V-240V) 20 A during 160 µs before the luminaire Inrush (380V-400V) 30 A during 160 µs Power Factor...
  • Page 9 ELECTRICAL CONNECTION FOR EVP500 DALI L< 50m DALI MAINS Cable from Driver box to Connection Box CONNECTION CONNECTION MAINS MAINS DALI STRIPPING LENGTH: 8-9 mm 8-9 mm Ø min Ø max TORQUE MAX VOLTAGE RECOMMENDED CABLE TYPE CONNECTOR (mm) (mm) SUPPORTED S E C T I O N H05VV-F (3182-Y) 2...
  • Page 10 T568B DMX (2 entries) Cable from Driver box to Connection Box MAINS Ø 13-18mm TERMINATOR RJ45 (not supplied by Philips) For safety reasons the terminator must have isolated housing MAINS CONNECTION BOX 1) Remove plugs only when needed STRIPPING LENGTH:...
  • Page 11 WIRING CONNECTION BOX L< 50m CABLE NOT SUPPLIED BY PHILIPS IN VERSION BV (7G 1.5/ 7G 2.5 mm2 ca- ble or 6G1,5 mm2 cable only for BVP518) UNLOSABLE SCREWS WITH RETAIN WASHERS BVP518 BVP528 1. Pull the gland outwards 2. Insert the cable 3.
  • Page 12 ELECTRICAL CONNECTION 50m < L< 200m 50m<L<200m CABLE NOT SUPPLIED BY PHILIPS IN VERSION BV 8G2,5 mm2 cable DRIVER LUMINAIRE 3-POLE TERMINAL BLOCK NOT SUPPLIED BY PHILIPS 12/24...
  • Page 13 Installation of drivers boxes on cabinet ORIENTATION DISTANCES Each driver box in the cabinet has to be in vertical position The distances between driver box- es or wall have to be higher than: Item Distance Min 50mm Min 80mm Min 50mm Min 150mm Min 200mm Cables...
  • Page 14 Installation of driver boxes in the mast minimum width of the door: 125mm minimum height of the door: 600mm Depending of the driver fixation in the mast, please select the most suitable hook. 14/24...
  • Page 15 Installation of driver boxes on the bracket or in horizontal position BOTTOM Breathers cannot be exposed directly to water Maximum number of luminaires to be connected to standard circuit breakers (fuse) BVP518 Mains voltage Max Nr luminaires BVP528 Mains voltage Max Nr luminaires connected connected MCB 16A A type 220V-240V...
  • Page 16 Have you already downloaded the Philips Service tag app? It helps you make LED maintenance easier and faster! PHOTOMETRICAL DATA ARE AVAILABLE ON SERVICETAG. THEY CAN BE OBTAINED USING THE QR CODE 16/24...
  • Page 17 17/24...
  • Page 18 18/24...
  • Page 19 Tímto prohlaŐuje, Ŭe typ rádiového zaňízení je v souladu se smĎrnicí 2014/53/EU. Úplné znĎní EU prohláŐení o shodĎ je k dispozici na této internetové adrese: http://www.philips.com/lighting potrjuje, da je tip radijske opreme skladen z Direktivo 2014/53/EU. Celotno besedilo izjave EU o skladnosti je na voljo na naslednjem spletnem naslovu: http://www.philips.com/lighting...
  • Page 20 GB - Disconnect before servicing DK - Frakobl, før service IT - Toglieretensioneprima di fare manutencione FR - Mettrehors tension avantintervention NO - Koble fra før service SP - Desconectarantes de manipular DE - Offnennurspannungsfrei FI - Irrota pistoke ennen huoltoa SE - Brytströmmenförelampbyte NL - Stroom afsluiten voor onderhoud CZ - Před servisem se odpojte...
  • Page 21 Opbevaring, installation, brug, betjening og vedligeholdelse af produkterne ma kun udfores ifolge instruktionerne i denne vejledning og/eller eventuelle ovrige instruktioner fra Philips Lighting for at garantere sikker brug af produktet i hele dets levetid. Hvis disse instruktioner ikke folges, bortfalder produktgarantien.
  • Page 22 Depozitarea, instalarea, utilizarea, operarea și întreșinerea produselor trebuie să fie efectuate exact în conformitate cu instrucșiunile din acest manual și/sau cu alte instrucșiuni care pot fi furnizate de noi pentru a garanta utilizarea în siguranșă a produsului, pe întreaga durată de viașă a acestuia. Nerespectarea acestor instrucșiuni vă...
  • Page 23 23/24...
  • Page 24 The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V..

This manual is also suitable for:

Bvp518Bvp528 hgbBvp528 bvBvp518 hgbBvp518 bv

Table of Contents