Huawei Airbridge cBTS3612 Maintenance Manual page 55

Cdma base station
Hide thumbs Also See for Airbridge cBTS3612:
Table of Contents

Advertisement

On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
Eliminate the BRDM, BCPM and BCKM faults;  
3)
4)
Replace the BTRM. 
Alarm on reverse signal strength indicator abnormal  
IV.
Abnormal reverse signal strength may block the reverse service
link. Check the antenna and feeder system for possible problem
causes.  
RS485 link failure  
V.
RS485 link failure will block the alarm messages of the fan
monitoring board from being reported to the BTRM, and thus result in
the closed-loop power control failure. Follow the handling process
below. Go to next step if the problem cannot be solved with the
current one:  
1)
Reinstall the relevant BHPA after power-off, then power on
again;  
2)
Replace the fan monitoring board (or the relevant BTS RF
Fan Module); 
Replace the BTRM ;  
3)
Replace the RF backplane.  
4)
Other problems with the BTRM  
VI.
Other problems with the BTRM include:  
Transmitting channel clock unlocked, hardware phase-lock
unlocked,
abnormal
frequency-converter failure.  
Chapter 3 Component Failure
I
value
and
0
3-18
Handling
the
digital
down

Advertisement

Table of Contents
loading

Table of Contents