Oml Failure; Fault Description; Troubleshooting - Huawei Airbridge cBTS3612 Maintenance Manual

Cdma base station
Hide thumbs Also See for Airbridge cBTS3612:
Table of Contents

Advertisement

On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
parameters, such as the BTRM ID, cell ID, cell resource pool ID and
optical interface ID, etc. Reconfigure those parameters if necessary.  
Incorrect physical board connection  
V.
Possible cause to BTS initialization failure due to incorrect
physical board connection:  
1) The boards are not installed properly and need to be
corrected;  
2) The optical fiber connection fault between the BRDM and
BTRM, you may need to refer to "3.2
Failure" for proper handling measures.  

2.4 OML Failure 

2.4.1 Fault Description  
After the BTS is powered on, the BOOTP process fails, the
attempt to establish OML signaling link of the OMC fails or the OML
breaks while the BTS is running.  
We can see the alarm "OML Failure" from the BTS maintenance
console.  

2.4.2 Troubleshooting 

The BTS OML connection starts from the BCKM and passes the
BCIM, the XIE board of BSC, the CMUX, the LPU board of the
switching subrack and the MPU board and ends at the BAM. Any
problem in any link of the route may lead to the OML failure.  
Chapter 2 General Fault
Handling of Common Board