On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
Whether the optical fiber of the BTRM and BRDM is
l
connected properly; 
Whether the BCIM is working properly; 
l
Whether the Abis signaling link is working properly; 
l
Whether the BSC is working properly; 
l
Whether the parameters in the BTS and BSC are in correct
l
corresponding relations. 
If there is a problem detected in a certain step, refer to the
relevant chapter for proper handling measures, for example, if there
is problem with the BTRM, go to "3.7
(BTRM )" for proper measures.  
IV.
Cell is blocked 
If we can see from the OMC console that the logic configuration
for the cell has been completed, but the MS still can not connect to
the network, we can then check whether this cell has been blocked.  
When a cell is blocked, the BTS will turn off the transmitting
signal of the BTRM, to which the carrier of this cell corresponds,
which will result in the MS network connection failure. 
We can use command "DSP BTSBRDSTAT" to query the BTRM
status on the OMC console and find out if the BTRM to which this
cell corresponds is blocked. 
If the cell is blocked, the mobile station will not be able to
connect to the network until the user unblock the cell. 
Chapter 2 General Fault