Download Print this page

Mitsubishi Electric 800 Series Manual page 70

Hide thumbs Also See for 800 Series:

Advertisement

Main circuit terminals
2.2
Main circuit terminals
 Terminal arrangement and wiring
FR-A820-00046(0.4K), 00077(0.75K)
R/L1 S/L2 T/L3
Jumper
R1/L11 S1/L21
N/-
P/+
M
Power supply
Motor
FR-A820-00630(11K)
FR-A840-00310(11K), 00380(15K)
R1/L11 S1/L21
Jumper
Charge lamp
R/L1
S/L2
Power supply
FR-A820-01870(37K), 02330(45K)
R/L1 S/L2 T/L3
N/-
P1
P/+
Jumper
Power supply
FR-A840-02160(75K), 02600(90K)
R/L1
S/L2
T/L3
N/-
Power supply
DC reactor
(option)

The following diagram shows the positions of R1/L11, S1/L21, and the charge lamp.

Terminals P3 and PR of the FR-A820-01540(30K) are not equipped with screws. Do not connect anything to these.

When an option other than the DC reactor must be connected to terminal P/+, use terminal P/+ (for option connection).
NOTE
• Make sure the power cables are connected to the R/L1, S/L2 and T/L3. (Phase need not be matched.) Never connect the power cable to the U, V and W of the
inverter. Doing so will damage the inverter.
• Connect the motor to U, V, and W. Turning ON the forward rotation switch (signal) at this time rotates the motor counterclockwise when viewed from the load shaft.
(The phase sequence must be matched.)
• The charge lamp will turn ON when the power is supplied to the main circuit.
• When wiring the inverter main circuit conductor of the FR-A840-05470(220K) or higher, tighten a nut from the right side of the conductor. When wiring two wires, place
wires on both sides of the conductor. (Refer to the following figure) For wiring, use bolts (nuts) provided with the inverter.
8
WIRING
FR-A820-00105(1.5K) to 00250(3.7K)
FR-A840-00023(0.4K) to 00126(3.7K)
Jumper
PR
Jumper
PX
Charge lamp
Power supply
FR-A820-00770(15K) to 01250(22K)
FR-A840-00470(18.5K), 00620(22K)
Jumper
P/+
PR
N/-
T/L3
M
Motor
Power supply
FR-A820-03160(55K)

R/L1 S/L2 T/L3 N/-
M
Motor
FR-A820-03800(75K), 04750(90K)

FR-A840-03250(110K) to 04810(185K)
P/+
P/+
M
Motor
P/+ (for option connection)
Jumper
R/L1 S/L2 T/L3
N/-
P/+ PR
PX
R1/L11 S1/L21
M
Charge lamp
Motor
R1/L11 S1/L21
Charge lamp
Jumper
P3
PR
P/+
R/L1 S/L2 T/L3
N/-
Jumper
M
Motor

P1
P/+
Jumper
M
Power supply
Motor


R/L1 S/L2 T/L3 N/-
P/+
P/+
M
Power supply
Motor
DC reactor
(option)
Charge lamp
Jumper
R1/L11 S1/L21
FR-A820-00340(5.5K), 00490(7.5K)
FR-A840-00170(5.5K), 00250(7.5K)
N/-
R1/L11 S1/L21
Jumper
R/L1 S/L2 T/L3
Charge lamp
M
Power supply
Motor
FR-A820-01540(30K)

FR-A840-00770(30K)
Charge lamp
Jumper
R1/L11 S1/L21
Jumper
P/+
R/L1
S/L2
T/L3
N/-
P3
PR
Power supply
FR-A840-00930(37K) to 01800(55K)

R/L1 S/L2 T/L3 N/-
P/+
P3
PR
Jumper
Power supply
FR-A840-05470(220K) to 06830(280K)
R/L1 S/L2 T/L3
N/-
P/+
P/+
Power supply
DC reactor
(option)
P/+ PR
Jumper
PX
M
Motor
M
Motor

M
Motor

Advertisement