Combination with the vector control dedicated motor
When using the inverter with a vector control dedicated motor, refer to the table below.
• Combination with the SF-V5RU and SF-THY (ND rating)
Voltage
Rated speed
Base frequency
Maximum speed
Motor frame
Motor capacity
1.5 kW
90L
2.2 kW
100L
3.7 kW
112M
5.5 kW
132S
7.5 kW
132M
11 kW
160M
15 kW
160L
18.5 kW
180M
22 kW
180M
30 kW
200L
37 kW
200L
45 kW
200L
55 kW
225S
75 kW
250MD
90 kW
250MD
110 kW
280MD

The maximum speed is 2400 r/min.

80% output in the high-speed range. (The output is reduced when the speed is 2400 r/min or faster.)
NOTE
• The SF-V5RU1 (speed ratio 1:1), SF-V5RU3 (speed ratio 1:3), and SF-V5RU4 (speed ratio 1:4) will be manufactured per
order.
400 V class
1500 r/min
50 Hz
3000 r/min
Motor model
number
SF-V5RUH1K
SF-V5RUH2K
SF-V5RUH3K
SF-V5RUH5K
SF-V5RUH7K
SF-V5RUH11K
SF-V5RUH15K
SF-V5RUH18K
SF-V5RUH22K
SF-V5RUH30K

SF-V5RUH37K

SF-V5RUH45K

SF-V5RUH55K

SF-THY
SF-THY
SF-THY
Parameter settings for a motor with encoder
Inverter model
FR-A846-[]
00083(2.2K)
00083(2.2K)
00126(3.7K)
00250(7.5K)
00310(11K)
00380(15K)
00470(18.5K)
00620(22K)
00770(30K)
00930(37K)
01160(45K)
01800(55K)
02160(75K)
02600(90K)
03250(110K)
03610(132K)