Refr gerant p p ng connect on

7.1 Note on p pe length

The length of refr gerant p p ng w ll affect the performance and energy eff c ency of the un t. Nom nal
eff c ency s tested on un ts w th a p pe length of 5 meters (16.5ft).
Refer to the table below for spec f cat ons on the max mum length and drop he ght of p p ng.
Max mum length and drop he ght of refr gerant p p ng per un t model
Model
R410A nverter spl t a r
cond t oner
7.2 Connect on nstruct ons – refr gerant p p ng
Step 1: Cut p pes
When prepar ng refr gerant p pes, take extra care to cut and flare them properly. Th s w ll ensure
eff c ent operat on and m n m ze the need for future ma ntenance.
1. Measure the d stance between the ndoor and outdoor un ts.
2. Us ng a p pe cutter, cut the p pe a l ttle longer than the measured d stance.
3. Make sure that the p pe s cut at a perfect 90° angle. Refer to F g. 7.1 for bad cut examples.
Spl t-type room a r cond t oner / Installat on Manual
Capac ty (BTU/h)
< 15,000
≥ 15,000 and < 24,000
≥ 24,000 and < 36,000
≥ 36,000 and ≤ 60,000
Max. length (m)
Max. drop he ght (m)
25 (82ft)
30 (98.5ft)
50 (164ft)
65 (213ft)
10 (33ft)
20 (66ft)
25 (82ft)
30 (98.5ft)