5
Indoor un t nstallat on
Rated current of appl ance (A)
Choose the r ght cable s ze
The s ze of the power supply cable, s gnal cable, fuse, and sw tch needed s determ ned by the
max mum current of the un t. The max mum current s nd cated on the nameplate located on the s de
panel of the un t. Refer to th s nameplate to choose the r ght cable, fuse, or sw tch.
Take note of fuse spec f cat ons
The a r cond t oner's c rcu t board (PCB) s des gned w th a fuse to prov de overcurrent protect on. The
spec f cat ons of the fuse are pr nted on the c rcu t board, such as: T3.15A/250VAC, T5A/250VAC, etc.
Indoor un t: T5A/250VAC
Outdoor un t (appl cable to un ts adpot R32 or R290 refr gerant only):
T20A/250VAC (<=18000Btu/h un ts)
T30A/250VAC (>18000Btu/h un ts)
C
Note: The fuse s made of ceram c.
Spl t-type room a r cond t oner / Installat on Manual
M n mum cross-sect onal area of power and s gnal cables
North Amer ca
Appl ance Amps (A)
10
13
18
25
30
Other reg ons
> 3 and ≤ 6
> 6 and ≤ 10
> 10 and ≤ 16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
COOL mode
18
16
14
12
10
Nom nal cross-sect onal area
(mm )
0.75
1
1.5
2.5
4
6