Download Print this page
Aqualisa HiQu HQD1002 Installation Manual

Aqualisa HiQu HQD1002 Installation Manual

Digital concealed

Advertisement

Quick Links

HiQu
TM
Digital
Concealed
Installation guide
HiQu Digital Concealed installation instructions
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the HiQu HQD1002 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aqualisa HiQu HQD1002

  • Page 1 HiQu Digital Concealed Installation guide HiQu Digital Concealed installation instructions Page 1...
  • Page 2 HiQu Digital Concealed HiQu Digital concealed HiQu Digital Concealed installation instructions Page 2...
  • Page 3 Components ( ( G G r r a a v v i i t t y y P P u u m m p p e e d d ) ) Components ( ( H H P P / / C C o o m m b b i i ) ) Literature not shown.
  • Page 4: Safety Information

    Important information Safety information This product must be installed by a competent person in accordance with all relevant current Water Supply Regulations. ALL SHOWERS REQUIRING AN ELECTRICAL CONNECTI0N MUST BE INSTALLED BY A QUALIFIED PERSON FOLLOWING THE LATEST REVISION OF BS 7671 (WIRING REGULATIONS) AND CERTIFIED TO CURRENT BUILDING REGULATIONS.
  • Page 5 Installation of Digital pumped processor (for gravity stored systems) The HiQu Digital pumped shower system is designed to operate up to maximum static pressure of 100kPa ((1 bar)(10 metres head)(14.5psi)). Under no circumstances must the pumped processor be connected directly to the water main or in line with another booster pump.
  • Page 6: Pipe Sizing

    Regulations prior to connection of the product. After installation Familiarise the end user with the HiQu Digital operation and hand them this guide. Complete and post the guarantee card or register online at www.aqualisa.co.uk HiQu Digital Concealed installation instructions Page 6...
  • Page 7 Installation instructions This product must be installed by a competent person in accordance with the relevant current Water Supply Regulations. In addition to the guide below it is essential that the written instructions overleaf are read and understood and that you have all the necessary components (shown overleaf) before commencing installation.
  • Page 8 Choose the position for your Digital processor as close to the shower control as possible. The processor may be sited in the roof space above the proposed shower site, in the airing cupboard or behind a screwed bath panel if more convenient.
  • Page 9 Attach the supply pipes to the Digital processor, ensuring that the cold and hot feeds are fitted into the appropriately marked inlets. DO NOT SOLDER NEAR TO PLASTIC COMPONENTS. Run a pipe from the mixed water outlet on the Digital processor through the wall to the proposed siting for the shower outlet.
  • Page 10 Apply a thin bead of mastic to the mastic groove at the rear of the back plate. Secure the back plate to the wall using the screws provided (if suitable). Connect the data cable to the rear of the controller. Hook the top of the controller into position and secure the controller onto the back plate assembly.
  • Page 11: This Appliance Must Be Earthed

    Connect the 15mm copper pipe to the mixed water outlet on the Digital processor. Using pipe clips as appropriate, ensure that all pipe work is perpendicular to the processor, i.e. not putting any strain on the fittings. TO ENSURE OPTIMUM PERFORMANCE USE THE MINIMUM AMOUNT OF ELBOWS.
  • Page 12 Unscrew the single fixing on top of the processor box and carefully tilt the lid up and off the location lugs and pull the lid clear. Connect the low voltage data cable into the socket adjacent to the temperature adjuster as indicated on the label.
  • Page 13 The Digital processors are supplied factory set with the flow rate at either ‘NORMAL HP’ or ‘NORMAL GRAVITY’ mode depending on which shower system has been ordered. STANDARD PROCESSORS ON BALANCED HP SYSTEMS: Standard processors fitted to balanced high pressure systems may be set to ‘NORMAL HP’ or for water economy ‘ECO’...
  • Page 14 Run the shower at maximum temperature (factory pre set to 45 C). If required, maximum temperature adjustment can be made with a flat bladed screwdriver using the ‘MAX’ TEMP ADJUSTMENT’ control as indicated. When the temperature has been set to the desired position carefully replace the Digital processor lid and secure the fixing hand tight only.
  • Page 15 Part No:700390 Issue 01 Jun 12 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter, change or modify the product specifications without prior warning ® Registered Trademark Aqualisa Products Limited...