NuAire DRIMASTER 365 Installation And Maintenance Details

NuAire DRIMASTER 365 Installation And Maintenance Details

Low energy positive input ventilation unit

Advertisement

Quick Links

1.0 Important notes to installers
The successful operation of this unit depends entirely upon
installation and ongoing maintenance being carried out strictly
in accordance with these instructions.
Please read this guide in its entirety before installation and then
repeat the exercise step by set to ensure satisfactory completion.
Suitably qualified persons may achieve installation of the unit,
however the provision of the electrical supply and the connection of
the unit to the mains supply should only be carried out by a qualified
electrician.
The unit can be installed in a home with a "cold roof" or "warm
roof". These instructions are limited to installation in a home
with a "cold roof". "Warm roofs" vary considerably and advice
should be sought from Nuaire on an individual basis.
2.0 General description
The unit is a unique Low Energy Positive Input Ventilation (LEPIV)
unit. Unlike conventional LEPIV units which only draw in external
air via the loft in a "cold roof', the unit is capable of drawing in
external air from different roof locations via three air inlet spigots
each fitted with their own low energy open/close damper. (See fig. 1).
Figure 1. General view of unit in a loft.
(Shown located on AV mounts).
Please note:
1. Only the items shown shaded
are supplied as standard with
the unit.
All other installation materials
(see table on page 3) must be
purchased separately by the
installer.
2. The 4 temperature sensors
(one for each of the air inlet
locations and one for the
home itself) and associated
sensor cables (15m long) are
also supplied with the unit.
3. The cable (10m long)
connecting the unit to the user
control is also supplied.
T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk
Low Energy Positive Input Ventilation Unit
DRIMASTER 365
Installation and Maintenance Details
Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA
The units airflow and the opening/closing of each air inlet damper
is controlled via an integral intelligent control system that measures,
and appropriately responds to, temperatures at the various air inlet
locations, the home itself, the "target temperature" selected by the
occupants on the user control panel provided and the delivered air
temperature into the home.
Power
Status
User control panel, located in the home.
1
Leaflet Number 671347 October 2007

Advertisement

loading
Need help?

Need help?

Do you have a question about the DRIMASTER 365 and is the answer not in the manual?

Questions and answers

Summary of Contents for NuAire DRIMASTER 365

  • Page 1 User control panel, located in the home. Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk Leaflet Number 671347 October 2007...
  • Page 2 200mm dia. spigot available from Nuaire and a “Fireblock” is down the longest lengths of the hallway or landing.
  • Page 3 AV mounting kit (See figure 6). 50mm Batt en 25x50 min. A.V. mount Please note that Nuaire do not supply any timber for the AV Ceiling 12mm joist clearance mounts or the installation of the plenum to the rear of the rafters.
  • Page 4 Installation and Maintenance Low Energy Positive Input Ventilation Unit 8.1 Via the loft space at high level through uninsulated ducting supplied by the installer Figure 7. 8.2 Via the loft space at low level through uninsulated ducting supplied by the installer Figure 8.
  • Page 5 Installation and Maintenance Low Energy Positive Input Ventilation Unit 8.5 Via roof tile vents by others and insulated ducting supplied by the installer Figure 11. 9.0 Connecting the temperature With the cable sensors installed as described above, attach the other ends of the cables to the appropriate connector block on the sensors to the main fan unit main unit.
  • Page 6 Installation and Maintenance Low Energy Positive Input Ventilation Unit 10.0 Electrical Connection Figure 14. Control module panel on unit (cover removed). Please note: the electrical connection of the unit must be be carried out by a qualified electrician. Electrical details:- Voltage: 240V 1ph 50Hz Consumption: 40W (max)
  • Page 7 When shows up release the button. required. New filters can be purchased direct from Nuaire using the following The led light should now be reset. code: 775631 (5 year filter). If the status light is permanently red, or if the units performance has 15.0 Warranty...
  • Page 8: Operation And Maintenance

    The equipment referred to in this Declaration of Incorporation is supplied by are not prevented by the equipment panels or by fixed installation detail Nuaire to be assembled into a ventilation system which may or may not include (eg ducting), then guarding to the appropriate standard must be fitted.