EST-X
Figure 1. EST-X unit.
A
Removable
top panel
D
Table 1. EST-X Dimensions (mm)
Code
A
B
EST1-X
705
505
EST2-X
875
720
EST3-X
970
720
EST4-X
1165
980
EST5-X
1165
980
EST6-X
1165
980
EST9-X
1495
1125
EST-R & EST-B
Figure 2. EST-R/B units.
Commissioning box
A
Opposed
outlet
grille
C
Control module
located internally
Table 2. EST-R / B Dimensions (mm)
Unit
A
B
C
EST1-R
705
505
355
EST1-B
705
505
355
EST2-R 875
720
400
EST2-B 875
720
400
EST3-R 970
720
485
EST3-B 970
720
485
EST4-R 1165
980
575
EST4-B 1165
980
575
EST5-R 1165
980
575
EST5-B 1165
980
575
EST6-R 1165
980
575
EST6-B 1165
980
575
EST9-R 1495
1125
710
EST9-B 1495
1125
710
T: 029 2085 8400 F: 029 2085 8444 E: info@nuaire.co.uk W: www.nuaire.co.uk
ECOSMART TWINFANS
(EST-X/R/B) 1 phase, Direct Drive,
Run & Standby
Roof Mounted and Internal use
For External,
Installation and Maintenance
B
Control module
located internally
External
Commissioning box
Weight
C
D dia.
(kg)
355
125
22
400
200
35
485
200
50
575
250
72
575
400
75
575
400
86
710
500
162
B
D
Removable
top panel
Circular inlet spigot
on end of unit
F
E
Code: EST*-R
Rectangular bottom
inlet spigot EST*- B only
Weight
D dia.
E
F
(kg)
125
-
-
22
-
76
152
22
200
-
-
35
-
127
229
35
200
-
-
45
-
127
229
45
250
-
-
72
-
152
305
72
400
-
-
75
-
229
457
75
400
-
-
86
-
229
457
86
500
-
-
162
-
304
762
162
Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA
Introduction
Units are rectangular in section and consist of three basic
designs.
Full size access panels are fitted to the top of the units and
are fully detachable for inspection and connection purposes.
The models are coded as follows:
EST-X (External/Internal Duct Mounted) in line unit.
C
EST-R (Roof Mounted, end inlet) side discharge unit.
EST-B (Roof Mounted bottom inlet) side discharge unit.
EST-X units are rectangular in section and have circular rigid
spigots at each end.
EST-R units are rectangular in section and are supplied with
a circular end spigot and two opposed side discharge grilles.
EST-B units are rectangular in section and have a rectangular
bottom spigot and two opposed side discharge grilles.
Handling
Always handle the units carefully to avoid damage and
distortion. If mechanical aids are used to lift the unit, spreaders
should be employed and positioned so as to prevent the slings,
webbing etc. making contact with the casing.
Installation
Installers - please note that Installation must be carried
out by competent personnel in accordance with the
appropriate authority and conforming to all statutory and
governing regulations e.g. I.E.E, CIBSE, COHSE.
EST-X/R/B units are suitable for internal or external use.
All units can be installed at any angle up to 60
sloping roof the unit must be blowing upwards toward the
roof ridge to ensure correct backdraught shutter operation.
Units should always be positioned with sufficient space to
allow removal of the access cover and subsequent removal
of fan and motor assemblies etc.
Whether internally or externally mounted, the method of fixing
to the roof is the responsibility of the installer.
All units have a bottom skirt to allow for fixing directly onto
a suitably sized curb or builders upstand. Nuaire can supply a
matching prefabricated curb for these units. Details of curbs
and dimensions for a suitable external concrete upstand are
shown on page 2.
Ductwork connections must be airtight to prevent any loss of
performance.
In High humidity applications above 90%
trickle ventilation is recommended.
1
The EMC Directive
2014/30/EU
The Low Voltage
directive
2014/35/EU
o
however, on a
16. 06. 15. Leaflet Number 671142