NuAire CYFAN-C Installation And Maintenance Manual

NuAire CYFAN-C Installation And Maintenance Manual

Extract fans, 230v/24v dc selv surface and semi-recessed mounted domestic fans

Advertisement

SECTION 1.0
INTRODUCTION
CYFAN-C EXTRACT FANS
The Nuaire CYFAN-C centrifugal extract fan is a major advance-
ment and has been designed to meet the flow rates for all wet
room applications such as the bathroom, kitchen, utility and WC
etc.
The unit discharges air through a 100mm or 125mm dia. spigot which
for surface and semi-recessed mounted units exits at the rear of the
unit. The subsidiary spigot kit allows the fan to extract air through the
side of the fan via a 50mm dia. spigot.
The motor is 24V brushless DC. Bearings are sealed, self-lubricating
ball type with integral locked rotor protection.
Units are supplied with a separate transformer enclosure if fans are
required for SELV usage.
Important
Warning: Isolate from power supply before removing any covers.
During installation/maintenance ensure all covers are fitted
before switching on the mains supply.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not
be made by children without supervision.
Precautions must be taken to avoid the back-flow of gases into
the room from the open flue of gas or other fuel-burning
appliances.
Means for disconnection must be incorporated in the fixed wiring
as shown in the wiring diagram in accordance with IEE wiring or
national wiring rules.
CAUTION: In order to avoid a hazard due to inadvertent resetting
of the thermal cut-out, this appliance must not be supplied
through an external switching device, such as a timer, or
connected to a circuit that is regularly switched on and off by
the utility.
*IPX4 to EN 60335-2-80 with front cover fitted.
Nuaire: A Trading Division of Polypipe Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA
CYFAN-C EXTRACT FANS
230V/24V DC SELV Surface and
Semi-Recessed Mounted Domestic Fans
INSTALLATION AND MAINTENANCE
T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk
1.1 Unit Operation includes 230V to 24V
conversion, continuous or intermittent
The fan can be converted to operate as a 24V DC SELV for zone 1
and 2 applications. The fan has the option to select continuous or
intermittent operation up to a installed performance of 60 l/s.

1.2 Mounting options

The CYFAN range can be:
Surface Mounted,
Semi-Recessed Mounted,
Using the optional extra Semi-Recessed
mounting frame kit suitable for 100mm and 125mm dia duct, consists of
mounting plate and mounting flange.
Window Mounted, using the optional
Surface mounted with side spigot, using the optional kit
(see accessories and kits for part numbers).
1.3 Accessories/kits available for CYFAN-C:
n Wall mounting kit
Product Code
Colour option
CYFAN-WALLKIT-WH
White
CYFAN-WALLKIT-BR
Brown
CYFAN-WALLKIT-COT
Cotwolds
CYFAN-WALLKIT-TC
Terracotta
n
Optional window mounting kit (Part number: CYFAN-WKIT).
n
Optional subsidiary spigot kit for ventilation of adjacent
bathroom/separate toilet (Part number: CYFAN-DKIT).
n
Semi-recessed mounting kit (Part number: CYFAN-RKIT).
n
Optional filter available (Part number: 7702017).
1.4 What comes in the box?
The following components are included.
Fan Body
n
Fan Scroll including Motor
and Removable Impeller
n
Control / PSU PCB, complete
with Boost Pull Switch
n
PCB Cover
n
Front Grille
n
Front Cover
n
125mm Spigot (fitted)
n
Additional 100mm dia. Spigot
n
2 off 100mm Back Draught Spigot
n
2 off 125mm Back Draught Spigot
n
24V Transformer Enclosure
0
1
inch
1
The EMC Directive
2014/30/EU
The Low Voltage
directive
2014/35/EU
IPX4
*
kit.
Fixing Kit
n
3
8 off No6 x
inch Pozi
4
Pan Screw
n
1
6 off No6 x
inch Pozi
2
Pan Screws
n
3
2 off No8 x
inch Pozi
8
Pan Screws
n
3 off Cable Clamps
n
1 off Shutter Spring
n
3 off Off nylon spacers
2
10. 05. 17. Leaflet Number 691500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYFAN-C and is the answer not in the manual?

Questions and answers

Summary of Contents for NuAire CYFAN-C

  • Page 1: Mounting Options

    *IPX4 to EN 60335-2-80 with front cover fitted. Nuaire: A Trading Division of Polypipe Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 10. 05. 17. Leaflet Number 691500...
  • Page 2 CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE 1.5 Fan Unit Dimensions (mm) SECTION 1.0 INTRODUCTION Front view CYFAN-C EXTRACT FANS Index Section 2 – Unit Preparation Page 3 Spigot Change Fitting back draught shutter 230V to 24V conversion All Wiring Diagrams Section 3 –...
  • Page 3: Section 2.0 Unit Preparation

    Fig 2. Fit spring to the bottom of the two shutters. Impeller. 2.1 How to change the spigot size The CYFAN-C is fitted with a 125mm dia. spigot, if a 100mm dia. spigot is required follow the following steps. Spring.
  • Page 4 CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE 2.4 Installation of Transformer Enclosure (24 Volt units only) SECTION 2.0 The enclosure containing the transformer is intended to be mounted out of sight (e.g. in a loft, cupboard, under floorboards etc.). UNIT PREPARATION CONT.
  • Page 5: Wiring Diagrams

    CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE SECTION 2.0 UNIT PREPARATION CONT. Isolation - Before commencing work make sure 2.7 Wiring diagrams that the unit, and Nuaire control are electrically isolated from the mains supply. 24V Wiring options. Fig 7. 24V SELV Wiring (via remote switch)
  • Page 6: Fan Installation

    CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE 5. Disconnect and remove the fan scroll from assembly and completely remove the PCB assembly. Note: if the pull cord is not required, remove it completely. SECTION 3.0 6. Core cut a hole through mounting surface at desired mounting...
  • Page 7 CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE 5. Partially remove the PCB assembly from the fan casing by placing a finger tip behind the dip switches and pulling the PCB away from the fan casing. (see fig 14). SECTION 3.0 6. Disconnect and remove the fan scroll from assembly and FITTING THE PRODUCT completely remove the PCB assembly.
  • Page 8 CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE Fig 17. Use cable clamp on rear of casing to secure wiring. SECTION 3.0 FITTING THE PRODUCT WINDOW MOUNTING 3.7 Fan installation Note: Window mounting requires the optional mounting kit: (Part number: CYFAN-WKIT). Installation must be completed by qualified personnel.
  • Page 9 CYFAN-C EXTRACT FANS INSTALLATION AND MAINTENANCE 8. Wire unit in accordance with the appropriate wiring diagram. A cable clamp is provided inside the case. Note: the remaining installation procedures for Window Mounting are as the SECTION 3.0 description in section 3.10.
  • Page 10 CYFAN EXTRACT FANS INSTALLATION AND MAINTENANCE SECTION 3.0 FITTING THE PRODUCT SURFACE MOUNTING WITH SIDE-SPIGOT Install the 50mm dia. subsidiary spigot from inside both the inner fan body and outer DKIT is recommended for Intermittent Extract Only. skirt, by ensuring both lugs have been passed through the cut-out.
  • Page 11: Fan Setting

    CYFAN EXTRACT FANS INSTALLATION AND MAINTENANCE 17. Secure skirt to wall (fixings supplied by others). Note: use wood screws not countersink screws to avoid distorting the skirt. SECTION 3.0 18. Feed cable through skirt and offer up fan case to skirt. Feed cable FITTING THE PRODUCT through unit and secure unit to skirt using 4x No6x1/2 inch screws SURFACE MOUNTING WITH...
  • Page 12: Warranty

    The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale. Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details. 5.2 After Sales For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department.