Download Print this page
Sealey Auto Service Line VS0565 Instructions

Sealey Auto Service Line VS0565 Instructions

Digital tyre depth gauge - pin tip

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
SAFETY INSTRUCTIONS.
1.
 WARNING! Ensure Health and Safety, local authority and general workshop practice
regulations are adhered to when using tools and equipment.
 DO NOT use gauge if damaged.
 Maintain gauge in good and clean condition for best performance.
 Keep the work area clean, uncluttered and ensure there is adequate lighting.
 Keep children and unauthorised persons away from the work area.
 DO NOT use the gauge for any purpose other than for which it is designed.
 DO NOT get gauge wet or use in damp or wet locations, or areas where there is
condensation. Keep gauge clean and dry using a dry cotton cloth only.
 DO NOT dip or submerge the gauge in any type of liquid.
 DO NOT expose gauge to bright sunlight or dust.
 DO NOT disassemble gauge. The gauge must be checked by qualified service personnel only.
 DO NOT apply any voltage to the gauge i.e. with an electric marker pen.
 The gauge is a precision instrument, treat with care, avoid using force and do not subject to
knocks or shocks.
 Use gauge in reasonably constant temperature conditions of approximately 20°C.
 When not in use, turn off and store gauge in a safe, dry, childproof location.
INTRODUCTION & SPECIFICATION.
2.
Hardened and tempered stainless steel gauge. 11mm high figures in LCD display for ease of
reading. Metric and Imperial calibration with conversion between the two. Zero setting control
allows for comparative measurement. Pin type tread-probe. Supplied with calibration certificate
and storage case.
Model No: ..................................................................VS0565
Range: ............................................................. 0-25mm (0-1")
Resolution:...................................................0.01mm(0.0005")
Accuracy: ..................................................±0.02mm (±0.001")
Battery Type: .......................................................SR44 - 1.5V
fig.1
fig.1
© Jack Sealey Limited
INSTRUCTIONS FOR:
DIGITAL TYRE DEPTH
GAUGE - PIN TIP
MODEL NO:
Original Language Version
VS0565
Item Description
1
Depth measuring probe
2
LCD Display
3
mm/inch Button
4
Locking screw
5
Foot
6
Power "ON/OFF" button
7
Zero set button
8
Battery cover
VS0565
ISSUE No:1 25/03/13

Advertisement

loading

Summary of Contents for Sealey Auto Service Line VS0565

  • Page 1 VS0565 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
  • Page 2 See Section 4.1 for battery removal. Dispose of batteries according to local authority guidelines. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme.