e
Installing Signal Monitoring Cables
NOTE
Before installing a signal monitoring cable, remove the cable already connected to the COM_IN port on the
CMUA board. Then, connect a cable of a proper length to the RTN 980.
•Mapping Relationships Between the Signals over Different Cables
8 7 6 5 4 3 2 1
NOTE
For cabinet sharing, the signal monitoring cable is not required for the RTN 980 .
UFLP
FE0
FE1
FE0
FE1
INSIDE
OUTSIDE
RJ-45 Connector of the Netw ork Port to the
Cable on the CMUA (COMIN) Board
Pin 1
TX+
Pin 2
TX-
Pin 4
RX+
Pin 5
RX-
Pin 8
GND
No
Pin 3/6/7
connected
COM_IN port
COM IN
CF RCV
RST
CSHN board
RJ-45 Connector (TOD2) of the Netw ork Port
to the Cable on the CSHN Board
White/Orange
Pin 6
Orange
Pin 3
Blue
Pin 8
White/Blue
Pin 7
Brow n
Pin 5
-
Pin 1/2/4
21
CMUA board
NMS/COM
EXT
CLK/TOD1 TOD2
TOD2 port
RX+
White/Orange
RX-
Orange
TX+
Blue
TX-
White/Blue
GND
Brow n
No
-
connected