W
10.2.2
List of Drive Error Messages
The following messages apply to the entire SD2x drive series. According to
the device type or operating mode, certain messages may not appear.
Code
Error message
E03
Interpolation error (interpolated
(0x103)
position control)
d )
(259
1
Acceleration limit exceeded
2
Speed limit exceeded
3
Index error
E05
Error caused by warning
(0x105)
d )
(261
E06
Digital Input 'External Hardware'
(0x106)
(262
d )
0
Digital input
1
Analog input 0: broken cable
2
Analog input 1: broken cable
3
Analog input 0 and 1: broken
cable
E07
Error in internal hardware
(0x107)
d )
(263
E09
Hiperface / EnDat OEM data
(0x109)
incorrect
d )
(265
E10
drive-setup-tool heartbeat
(0x10A)
d )
(266
E11
Communication / bus system error
(0x10B)
▶
1
SERVOLINK 4
(267
d )
▶
2
DNC 8 Byte
▶
3
CAN bus
▶
4
EtherCAT
1
Faulty telegram ID
2
Zero data telegram
3
1
CRC error
4
Synchronization error
5
Configuration error
6
2, 3, 4
NMT error
7
Addressing error
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
Error reaction
Motor is stopped by quick stop
ramp and drive is disabled
(controlled standstill).
Motor is stopped by quick stop
ramp and drive is disabled
(controlled standstill).
Motor is stopped by parameter-
driven ramp and drive is disabled
(controlled standstill).
Motor is stopped by quick stop
ramp and drive is disabled
(controlled standstill).
No "Ready" for startup
Motor is stopped by quick stop
ramp and drive is disabled
(controlled standstill).
Motor is stopped by parameter-
driven ramp and drive is disabled
(controlled standstill).
1
1
1, 4
4
4
Status Display and Error Messages
Possible reason
▶
Faulty motion profile of the higher-
ranking control
▶
Parameter-driven
stopped the drive.
Monitoring of external hardware:
0
Digital input "External Hardware
OK" is not connected to 24 V.
1
Minimum current monitoring of
analog input 0 has triggered.
2
Minimum current monitoring of
analog input 1 has triggered.
3
Minimum current monitorings of
analog inputs 0 and 1 have trig‐
gered.
▶
Overload in digital outputs
▶
SD2B plus: Operating voltage not
available
▶
Number of motor pole pairs in
EnDat/Hiperface encoder does not
match the parameter set.
drive-setup-tool was not able to
▶
communicate with the drive in the
parameterized monitoring time.
Monitoring of bus communication led to
switch-off:
1
Faulty reference value telegram
2
Higher-ranking control not active
3
Check sum error, interferences
during transmission
4
Drive telegram not synchronized
5
Faulty configuration of mailbox,
PDO, watchdog or synchronization
6
Control channel of bus system
was not active during switch-on
(pre-operational)
7
Faulty drive address
monitoring
10
83