  • Page 1 — SAFETY PRODUCTS Eden OSSD Coded non-contact safety sensor Product Manual 2TLC172272M0201 Rev E...
  • Page 2 ABB JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ABB JOKAB SAFETY. ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, REGARDING NON-...
  • Page 3: Table Of Contents

    Table of Contents Introduction ..........................5 Scope ..............................5 Audience ..............................5 Prerequisites ............................5 Special notes ............................5 Overview ..........................6 General description ..........................6 Safety regulations ..........................6 Models of Adam and Eva ....................... 7 Adam OSSD............................7 Eva ................................
  • Page 4 Testing the safety functions ......................20 LED indication ........................21 Maintenance ......................... 22 Troubleshooting ..........................22 Model overview ........................23 Accessories ............................23 Cables ..............................24 10 Technical data ........................25 Guideline for chemical resistance ...................... 27 Eden dimensions ..........................28 CAD model ............................
  • Page 5: Introduction

    This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB Jokab Safety products. • Knowledge of machine safety. Special notes Pay attention to the following special notes in the document:...
  • Page 6: Overview

    2 Overview General description Eden OSSD sensor consists of two separate devices – Adam and Eva – intended to use as interlocking device for gates, hatches etc. Eva can be general coded or unique coded. Eden OSSD meets the coding requirements according to EN ISO 14119:2013 regarding manipulation protection.
  • Page 7: Models Of Adam And Eva

    3 Models of Adam and Eva Eden communicates with OSSD signals and can be connected to any safety module that handles OSSD-signals. Up to 30 Eden sensors can be connected in series without reducing the achieved performance level. Adam and Eva are acquired separately and it is possible to mix different models of Adam OSSD in the same safety circuit.
  • Page 8: Electrical Connections

    4 Electrical connections NB: Use a suitably insulated low-voltage supply system type SELV or PELV. Adam OSSD-Info M12-8 M12 8-pole male M12 8-pole female from cable side from cable side M12-connector: (8-pole male) White: OSSD signal 1 Out 2) Brown: +24 VDC 3) Green: OSSD signal 1 In...
  • Page 9: Adam Ossd-Info M12-5

    OSSD signal 1 Out 3) Blue: 4) Black: OSSD signal 2 Out 5) Grey: Reset/Indication NB: The use of shielded cable is recommended for enhanced electromagnetic immunity. Caution! All cable colours according to ABB Jokab Safety standard cables. 2TLC172272M0201 Rev E...
  • Page 10: Connection Of Cable C5, C8 In M12 C01-C04 Connectors

    Connection of cable C5, C8 in M12 C01-C04 connectors Female 5-pin connector (M12 C01): 1 ) Brown 2 ) White Male 5-pin connector (M12 C02): 3 ) Blue 4 ) Black 5 ) Grey Female 8-pin connector (M12 C03): 1 ) White 2 ) Brown 3 ) Green Male 8-pin connector (M12 C04):...
  • Page 11: Connection Of Reset Button On Adam Ossd-Reset

    The maximum current consumption for the indication lamp is 30 mA. Smile 12RF and Smile 12RG are Reset buttons with indication lamps from ABB Jokab Safety indented to be used together with Adam OSSD-Reset. The minimum current consumption needed through the lamp is 10 mA. If no lamp is used, a 4.7 kOhm resistor can be used instead.
  • Page 12 Serial connection of three Adam OSSD-Reset M12-8 through M12-3G with Smile 12RG to a safety relay, Pluto or another safety-PLC (i.e. ABB AC500-S). 2TLC172272M0201 Rev E...
  • Page 13 Individual connection of three Adam OSSD-Reset M12-5 with Smile 12RF to a Pluto or another safety-PLC (i.e. ABB AC500-S). 2TLC172272M0201 Rev E...
  • Page 14: Connection Examples

    5 Connection examples Adam OSSD-Info connected to RT9 A) Adam OSSD-M12-5 connected to RT9 B) Adam OSSD-M12-5 connected to RT9 with automatic reset. with manual reset. Several Adam OSSD-Info connected in series A) Three Adam OSSD-M12-8 connected in series. 2TLC172272M0201 Rev E...
  • Page 15: Installation

    6 Installation General information Warning! All the safety functions must be tested before starting up the system. • Note that the detection distance can be affected when Eden is mounted close to metal. • The Eden can be mounted on metal, but should not be surrounded. •...
  • Page 16: Detection Distance

    Detection distance Eva can be turned in a number of different ways relative to Adam, see details in the figure below. The green fields in the picture show the detection distance of Adam relative to Eva. The safety signal is high when the two coils in Eva is in contact with the green field. The figure above shows maximum detection distances.
  • Page 17: Mounting

    Mounting Depending on the cable connector used for the connection to Eden, one or two distance plates might be required for correct mounting in order to avoid damaging Adam. It is recommended to use the distance plates (DA 1B) supplied with the Adam models with M12 connector (Adam M12), see figure below.
  • Page 18: Mounting Procedure

    DA 2B Mounting procedure Fasten each sensor with two M4 screws. Safety screw SM4x20 (2TLA020053R4200) is recommended. The DA 2B mounting spacer must be used in order to physically protect Eden from damage. 2. Use max tightening torque 1.0 Nm on screws. 3.
  • Page 19: Teaching The Code

    Teaching the code Adam is delivered without code and need to be programmed with the code from an Eva (General or Unique coded). The code of the first Eva detected by the Adam is automatically programmed as soon as Eva is within the detection distance. If Adam is programmed to accept an Eva with a general code, it will accept all Eva units with a general code.
  • Page 20: How To Erase Existing Codes From Adam M12-8

    How to erase existing codes from Adam M12-8 Remove Eva from Adam’s detection range. 2. Disconnect the power supply on pin 2 on the Adam unit. 3. Connect +24 VDC to pin 1 and 6. 4. Connect the power supply on pin 2 on the Adam unit. 5.
  • Page 21: Led Indication

    7 LED indication The non-safe status LED on Adam shows the status of the Eden sensor and the output status as follows: LED on Adam Description Safety circuit Green Valid Eva within range Closed Flashing green Valid Eva within range, waiting for reset Open Flashing red/green Valid Eva within range, no valid in signal...
  • Page 22: Maintenance

    (EN 62061:2005). Warning! In case of breakdown or damage to the product, contact ABB Jokab Safety. Do not try to repair the product. It might accidentally cause permanent damage, impairing the safety of the device and in turn lead to serious personnel injuries.
  • Page 23: Model Overview

    9 Model overview Type Article number Description Adam OSSD-Info M12-5 2TLA020051R5400 Pin 5: Information Adam OSSD-Info M12-8 2TLA020051R5700 Pin 5 and 8: Information Adam OSSD-Reset M12-5 2TLA020051R5600 Pin 5: Reset/Indication Adam OSSD-Reset M12-8 2TLA020051R5900 Pin 5: Reset/Indication, Pin 8: Information Eva General code 2TLA020046R0800 General code...
  • Page 24: Cables

    Cables Type Article number Description M12-C61 2TLA020056R0000 6 m cable 5 x 0.34 mm Shielded cable with straight M12 female connector M12-C101 2TLA020056R1000 10 m cable 5 x 0.34 mm Shielded cable with straight M12 female connector. M12-C201 2TLA020056R1400 20 m cable 5 x 0.34 mm Shielded cable with straight M12 female connector.
  • Page 25: Technical Data

    10 Technical data Manufacturer Address ABB Electrification Sweden AB, Jokab Safety Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden Power supply Rated operating voltage +24 VDC +15 % -40 % Use SELV/PELV Total current consumption 30 mA at +24 VDC 35 mA at 18 VDC...
  • Page 26 Information for use in USA / Canada Enclosure Type 1, 4, 4x Intended use Applications according to NFPA 79 Power source Only suitable for use in a limited voltage / current circuitry. The limited voltage / current source must comply with one of the following: a) An isolating device such that the maximum open circuit voltage potential available to the circuit is not more than +24 VDC and the current is limited to a value not exceeding 8 A measured after 1 min of...
  • Page 27: Guideline For Chemical Resistance

    Guideline for chemical resistance Chemicals Eden OSSD Hydrocarbons aliphatic Good aromatic Good halogenated - fully Poor/Fair - partly Poor Alcohols Good Phenols Poor Ketones Fair/Good Amines Not tested Esters Fair/Good Ethers Good Acids inorganic Good organic Fair oxidizing Poor Alkalis...
  • Page 28: Eden Dimensions

    Eden dimensions Adam M12, 5 pole Adam M12, 8 pole female. Contact female. Contact seen seen from cable from cable side. side. NB: All dimensions in millimetres. CAD model For CAD models please visit www.abb.com/jokabsafety. 2TLC172272M0201 Rev E...
  • Page 29: Ec Declaration Of Conformity

    11 EC Declaration of conformity 2TLC172272M0201 Rev E...