Nokia NHM-1 Series Troubleshooting Instructions page 6

Ccs technical documentation
Hide thumbs Also See for NHM-1 Series:
Table of Contents

Advertisement

NHM-1
Troubleshooting instructions
Connect a RF-cable to the module test jig (MJS-46) RF connector to and to measurement
equipment or at least 10dB attenuator, otherfwise the PA may be damaged. Normally
Spectrum analyzer is used as measurement equipment.
Attention: Normally Spectrum analyzer maximum input power is +30dBm. It is recom-
mended to use 10dB attenuator on Spectrum analyzer input to prevent damage.
Set the phone module to test jig and start Phoenix service sofware
Initialize connection to phone. (use FBUS driver when using DAU9S and COMBOX driver
when using FPS-8)
Select product from the menu
File -> Open product -> NHM-1
From toolbar
- Set system mode to "GSM"
- Set operating mode to "Local"
Activate RF controls window from the menu
Maintenance -> Testing -> RF Controls
From the RF controls window
- Select system mode "GSM"
- Select band "GSM900" or "GSM 1800" (Default = "GSM900")
- Set Active unit to "Tx" (Default = "Rx")
- Set Operation mode to "Burst" (Default = "Burst")
- Set Tx data type to "Random" (Default = "All1")
- Set Rx/Tx channel to 37 on GSM900 band or 700 on GSM1800 band (Defaults)
- Set Tx PA mode to "Free" (Default)
- Set power level to 5 (Default = 19) on GSM900 or to 0 (Default = 15) on
GSM1800
Page 6
Nokia Corporation.
CCS Technical Documentation
Issue 1 11/03

Advertisement

Table of Contents
loading

Table of Contents