2.10

M+RJ71C24_ExeCommonProtocol

Overview

Executes the protocol registered with GX Works3.
(1)
B: i_bEN
(2)
DUT: i_stModule
(3)
UW:
i_
uCh
(4)
UW:
i_
uNumberOfExecutions
(5)
UW:
i_
uExeProtocolNo

Labels

Input label
No.
Label
(1)
i_bEN
(2)
i_stModule
(3)
i_uCh
(4)
i_uNumberOfExecutions
(5)
i_uExeProtocolNo
2 SERIAL COMMUNICATION MODULE FB
28
2.10 M+RJ71C24_ExeCommonProtocol
M+RJ71C24_ExeCommonProtocol
o_bENO: B
o_bOK: B
o_bErr: B
o_uErrId: UW
o_ u NumberOfExecutions: UW
o_ uMatchPacketNo: UW
Label name
Data type
Execution
Bit
command
Module label
Structures
Communication
Word [Unsigned]/Bit
channel
String [16-bit]
Number of
Word [Unsigned]/Bit
continuous
String [16-bit]
protocol
executions
Execution
Word [Unsigned]/Bit
protocol number
String [16-bit] (0..7)
specification
(6)
(7)
(8)
(9)
(10)
(11)
Range
Description
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
Specify the module to execute this FB.
Specify the module label of relevant modules.
(example: C24_1)
1, 2
Set the channel to communicate with the external
device.
• 1: Channel 1 (CH1 side)
• 2: Channel 2 (CH2 side)
1 to 8
Set the number of continuous executions of the protocol.
1 to 128, 201 to
Set the protocol number or the special protocol number
207
to be executed. Protocols are executed in the specified
order of the execution protocol numbers.
+0
+7
Specify the device or label in which the protocol number
to be executed is stored. (Constants cannot be
specified.)
When it is specified using the label, use "ARRAY" for the
data type.
Execution protocol
number specification 1
Execution protocol
number specification 8