Bosch Rexroth ID 40 Manual page 82

Table of Contents

Advertisement

82/176
Interbus
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
Stage 2: If measurement data is available during processing, the parameters for
pretransmit are set (e.g., 80 bytes as of MDT address 0x01C0) and configured as a
single transmit (see Chapter 6.4.2 "Pretransmit"). By this time, the workpiece pallet
has lowered. The SLK switches to CONNECTING and the MDT immediately signs on
and executes the pretransmit.
No.
PCP
Index
communication
1
Begin setting
0x5FF1 0x0000
pretransmit
parameters
2
Delete pretrans-
0x5FF1 0x0004
mit data from
last MDT
3
Set param-
0x5FF0
eters for 80-byte
measurement
data block as
pretransmit
1
Finish setting
0x5FF1 0x0001
pretransmit
parameters
1
Activate single
0x5FF1 0x0002
transmit
4
Wait until lift positioning unit in lower position
5
Make SLK
Via process data channel:
ready to receive
(CONNECT)
Byte 0: 0x81 (switch trigger bit: now 1, used to be 0)
6
Wait until event counter in event-oriented data channel increases by 1. At this time, the
measurement data is written to the MDT and the link is DISCONNECTED (auto reconnect is
still active)
7
Make the
Via process data channel:
SLK ready to
receive the
Byte 0: 0x01 (switch trigger bit: now 0, used to be 1)
next workpiece
pallet only once
the current
workpiece
pallet is gone
(CONNECT)
Subindex 0
Subindex 1
Subindex 2
0x00020000
0x0001
Subindex 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents