Download Print this page

Mitsubishi Electric PAC-IF033B-E Operation Manual page 5

Flow temp. controller 2br (cased)
Hide thumbs Also See for PAC-IF033B-E:

Advertisement

2 . C u s t o m i s i ng s et t i ng s f o r y o u r h o m e
M a i n m enu
The following items can be viewed and/or edited (dependent on access level).
• Water temp. setting (Installer level)
• Compensation curve
• Initial settings
• Service (Password protected)
Use the F2 and F3 buttons to move between the icons. The highlighted icon will appear as a larger version in the cen-
tre of the screen. Press CONFIRM to select and edit the highlighted mode.
I ni t i a l s et t i ng s
From the Initial settings menu the installer can set the following.
• Date/Time
• Language
• ºC/ºF
• Temp. display
• Contact number
• Time display
• Main/Sub
1. Use buttons F1 and F2 to move scroll through the menu list. When the title is highlighted press CONFIRM to edit.
2. Use function buttons appropriate to edit each setting then press CONFIRM to save the setting.
Note: F or Main/Sub setting, select "Main" (Initial setting). Do not change the setting to "Sub", it is not avail-
able with FTC2BR.
W a t er t em p . s et t i ng
Set the initial value of the set water temperature for following modes.
• DHW mode
• Heating mode
• Cooling mode
• Holiday mode
The set water temperature is changeable in main screen during operation.
C o m p ens a t i o n c u r v e
During late spring and summer usually the demand for space heating is reduced. To prevent the heat pump from
producing excessive flow temperatures for the primary circuit the compensation curve mode can be used to maximise
efficiency and reduce running costs. The compensation curve is used to restrict the flow temperature of the primary
space heating circuit dependent on the outdoor ambient temperature. The FTC2BR uses information from both an
outdoor ambient temperature sensor and a temperature sensor on the primary circuit supply to ensure the heat pump is
not producing excessive flow temperatures if the weather conditions do not require it.
Preview:
You can check the target water temperature in compensation curve. Select outdoor ambient temp. with F3 and F4 buttons.
H o l i d a y m o d e
From the main menu screen press button E, the holiday mode activation screen will
be displayed. Be careful not to hold down button E for too long as this will turn off
the controller and system.
Once the holiday mode activation screen is displayed you can select the duration
that you would like holiday mode to run for.
• Use buttons F2, F3 and F4 to input the date which you would like holiday mode
to activate or deactivate for space heating.
S er v i c e M enu
The service menu provides functions for use by installer or service engineer. It is NOT intended the home owner alters
settings within this menu. It is for this reason password protection is required to prevent unauthorised access to the
service settings.
Icon
Description
Water temp.
Compensation curve
Initial settings
Service
Holiday Mode activation screen