Section 3 - Installation (ATSC EC702HP Transmitter)
B- AC power cables and exciter's grounding
Connect the AC feeding pigtail to the identified 3-pin connector located in the left side of the
each Digital Exciter drawer's rear panel.
Connect the grounding mesh in the GND screw on the rear panel of each digital exciter.
GND: Ground - Connect this terminal to ground at the installation site.
Manual Rev. 0.0 - April 2016
AC Input cable, ON/OFF switch and fusible - Module 40153
SCREW GROUNDING
Screw grounding - Digital Exciters
Figure 3-49
Figure 3-50
EXCITER A
EXCITER B
EXCITER A
EXCITER B
3-37