Operation Manuals
Before using the InterlockConfigTool, please read this manual carefully
to ensure proper operation.
Retain this manual for future reference.
1. Safety Precautions ..................................................................... 1
2. Introduction ................................................................................. 2
3. System Requirements ................................................................ 5
4. Installation and Uninstallation ..................................................... 6
4.1 Installation .......................................................................................6
4.2 Uninstallation .................................................................................10
5. Operating Instructions ...............................................................11
5.1 Exporting the Initial Settings of the EB-50 ..................................... 11
5.2 Starting Up the InterlockConfigTool ...............................................13
5.3.1 Interlock Control List .................................................................. 15
5.4 Editing the Interlock Settings .........................................................16
5.4.1 List of Interlock Setting Items ..................................................... 19
5.4.2 Setting the Air Directions ............................................................ 21
5.4.3 Setting the Fan Speeds .............................................................. 22
5.5 Selecting Equipment Types ...........................................................23
5.6 Confirming the Interlock Settings ..................................................25
5.7 Saving the Interlock Control Settings ............................................26
5.8 Exporting the Initial Settings in a CSV File ....................................27
5.9 Importing the Initial Settings into the EB-50 ..................................28
6. Error Message List ................................................................... 31
CONTENTS
WT07019X01

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric EB-50GU-A

  • Page 1: Table Of Contents

    EB-50GU-A/EB-50GU-J - Compatible InterlockConfigTool Operation Manuals CONTENTS 1. Safety Precautions ..............1 2. Introduction ................. 2 3. System Requirements ..............5 4. Installation and Uninstallation ............. 6 4.1 Installation ..................6 4.2 Uninstallation .................10 5. Operating Instructions ...............11 5.1 Exporting the Initial Settings of the EB-50 ........11 5.2 Starting Up the InterlockConfigTool ..........13...
  • Page 2: Safety Precautions

    Internet. Important Notice to the Users (License Agreement) This document serves as an agreement between the user of the application software and Mitsubishi Electric Corporation. By using this product, you agree to the following terms: Mitsubishi Electric Corporation and its associated dealers, under any circumstances, accept no liability for any direct, indirect, special, incidental, punitive, or any other damages or losses, even if the seller is notified of the possibility of such damages.
  • Page 3: Introduction

    2. Introduction EB-50GU-A/EB-50GU-J - Compatible InterlockConfigTool is a tool you can use to verify or change EB-50's Interlock control settings.s EB-50GU-A and EB-50GU-J are collectively referred to as EB-50 (1) InterlockConfigTool allows its users to verify or change the current Interlock control settings, using the EB-50’s Initial Settings exported to an HDD or a USB memory.
  • Page 4 Important Before using the interlock control, you must agree to the following. 1. Before making the settings for the Interlock Control Functions, thoroughly read the section “Web browser for Initial Settings” in the EB-50 Operation Manual. 2. This feature must not be used for disaster prevention or security purposes unless a backup device is provided in case of failure of this feature.
  • Page 5 Sample system configuration for the InterlockConfigTool [Sample system] (1) Initial Settings export to an HDD or a USB memory EB-50 USB memory (2) Importing to InterlockConfigTool InterlockConfigTool USB memory (3) Exporting the Initial Settings in a CSV File InterlockConfigTool CSV File (4) Confirming or Editing the Interlock setting InterlockConfigTool (5) Exporting to an HDD or an USB memory...
  • Page 6: System Requirements

    3. System Requirements To use the EB-50GU-A/EB-50GU-J-compatible InterlockConfigTool, the following system requirements must be met. Specifications PC/AT-compatible ® ® Microsoft Windows Vista Business 32-bit Service Pack 2 ® ® Microsoft Windows 7 Professional 32- or 64-bit Service Pack 1 ®...
  • Page 7: Installation And Uninstallation

    4. Installation and Uninstallation 4.1 Installation Installing the InterlockConfigTool Important ・Windows 8 may not have .NET Framework 2.0 installed as a standard application, and installation of .NET Framework 2.0 requires an Internet connection. If the computer on which the InterlockConfigTool will be installed does not have an active Internet connection, have the .NET Framework 2.0 installation file ready by following the instructions detailed under [Installation Procedures: .NET Framework 2.0].
  • Page 8 (6) Click “Next” on the next screen to start the installation process. Wait until installation is complete. (7) The window shown at right will appear upon completion of the installation. Click “Close” to exit the installation application.
  • Page 9 [Installation Procedures: .NET Framework 2.0]. Follow the procedures below to install [.NET Framework 2.0] on Windows 8. (1) Open “Control Panel”. (2) Click “Programs and Features” in “Control Panel”. (3) Click “Turn Windows features on or off”. (4) Check the checkbox next to “.NET Framework 3.5 (includes .NET 2.0 and 3.0)”...
  • Page 10 (5) Click “Download files from Windows Update”. File download will automatically start. Important ・Internet access is required to download files.
  • Page 11: Uninstallation

    4.2 Uninstallation Follow the steps below to uninstall the InterlockConfigTool. [Uninstallation Procedures: Windows 8] (1) Launch “Programs and Features” in "Control Panel.” (2) Click “InterlockConfigToolEB50” on the list, and then click “Uninstall.” [Uninstallation Procedures: Windows 7] (1) Launch “Programs and Features” in “Control Panel.” (2) Click “InterlockConfigToolEB50”...
  • Page 12: Operating Instructions

    5. Operating Instructions 5.1 Exporting the Initial Settings of the EB-50 How to export the Initial Settings from the EB-50 to be used with the InterlockConfigTool will be explained below. Important ・Before using the InterlockConfigTool, make sure the Interlock Control license for the EB-50 is valid.
  • Page 13 (4) To back up the data, click [Back up settings data].The settings data will be created and the Window’s standard file download dialog will appear. After that, this data can be exported to an HDD or a USB memory. Note: It will take a few minutes to create the settings data. Note: The name of the settings data will be “SettingData.dat”.
  • Page 14: Starting Up The Interlockconfigtool

    5.2 Starting Up the InterlockConfigTool [Operating Procedures] (1) If using USB memory with the EB-50’s Initial Settings data, before launching the InterlockConfigTool, insert the USB memory into the USB port on the computer. Note ・Back up the data on the USB memory drive on to a computer before using the InterlockConfigTool. (2) From the Desktop or Start menu, click the InterlockConfigToolEB50 icon to launch the...
  • Page 15: Operating Instructions For The Interlock Control List

    5.3 Operating Instructions for the Interlock Control List The current interlock settings can be verified on the Interlock control list. By selecting a specific row, its detailed settings can be viewed and/or changed, using the menu bar at the left top or the buttons on the right side of the screen.
  • Page 16: Interlock Control List

    5.3.1 Interlock Control List Function Explanation File Open *1 Opens the temporarily saved Interlock control settings file. Close *1 Closes the Interlock control settings being edited. Save Saves the Interlock control settings being edited. CSV output Exports the Interlock control settings being edited in a CSV file. Refer to section 5.8 “Exporting the Initial Settings in a CSV file”...
  • Page 17: Editing The Interlock Settings

    5.4 Editing the Interlock Settings The interlock settings for the selected rows can be edited, or a new set of interlock settings can be created as explained below. Refer to the section [Operating Procedures 1: Creating new interlock settings] for how to create new interlock settings.
  • Page 18 (5) Select Input Units by clicking "Select Units” at the left bottom of the screen. Refer to section 5.5 “Selecting Equipment Types” for details. (6) Select the Output Unit Type. Note ・The “Interlock Operation” and the “Output Unit Selection” buttons will be available for selection when Output Unit Type is selected.
  • Page 19 [Operating Procedures 2: Editing the existing interlock settings] (1) Select a desired row to change its settings from the Interlock control list. (2) Click “Config” on the right side of the “Interlock control list”, or select “Config” from the menu. (3) A settings configuration window will appear.
  • Page 20: List Of Interlock Setting Items

    5.4.1 List of Interlock Setting Items Important ・The available settings for certain items such as “Mode” and “Fan Speed” depend on the type of indoor units connected. Making the “Input State” or “Interlock Operation” settings not supported by the connected indoor units may cause equipment trouble. Before making these settings, make sure the function is supported by the indoor units.
  • Page 21 Summarized in the table below are the Interlock Operation Settings options for the system whose “Output Unit Type” is set to “Group.” Interlock Operation Setting Function Interlock ON/OFF Turns on or off the interlocked equipments when the input conditions are met. Operation No interlock operations will be performed when this item is set to “- -.”...
  • Page 22: Setting The Air Directions

    5.4.2 Setting the Air Directions The available air direction settings depend on the indoor unit model. Refer to the table below for the type of air flow directions that are available for the 4-speed and 5-speed models. Indoor Unit Model Setting 4-speed model Mid3...
  • Page 23: Setting The Fan Speeds

    5.4.3 Setting the Fan Speeds The available Fan Speed settings depend on the indoor unit model. Refer to the table below for the type of Fan Speeds that are available for different models. Model Setting Indoor 2-speed unit model Mid2 High Auto 3-speed...
  • Page 24: Selecting Equipment Types

    5.5 Selecting Equipment Types To select Input and Output units, follow the steps below. Click “Select Units” on the “Input Category” to select Input Units, and click “Select Units” on the “Output Unit Type” to select the Output Units. Equipment Icon Selection Pane The number of selected Groups on the The number of selected...
  • Page 25 When “Input Category” is set to “Free Input Points” and “Output Unit Type” is set to “Free Output Points”: Click the icon of the group to which the “Free Input Points/ Free Output Points” to be selected belong. Check the ON/OFF checkboxes next to the desired “Contact Point No.”...
  • Page 26: Confirming The Interlock Settings

    5.6 Confirming the Interlock Settings To confirm the interlock settings, follow the steps below. [Operating Procedures] (1) From the “Interlock control list,” click the desired row to confirm its settings. (2) Click “Confirm” on the right side of the “Interlock control list,” or select “Confirm” from the menu. (3) A confirmation screen will appear.
  • Page 27: Saving The Interlock Control Settings

    5.7 Saving the Interlock Control Settings To save the Interlock control settings being edited, follow the steps below. [Data Saving Procedures] (1) Select “Save” from the Menu. (2) On the next screen, name the file, select a destination, and save the settings. (3) A progress bar will appear to indicate the progress of the data storage process.
  • Page 28: Exporting The Initial Settings In A Csv File

    5.8 Exporting the Initial Settings in a CSV File To export the interlock settings in a CSV file, follow the steps below. The exported CSV file can be opened in ® spreadsheet software, such as Microsoft Excel. Note ・If a CSV file is not properly displayed in a spreadsheet software, change the delimiter settings from the Menu.
  • Page 29: Importing The Initial Settings Into The Eb-50

    5.9 Importing the Initial Settings into the EB-50 The data edited with the InterlockConfigTool can be exported and then imported into the EB-50 without the need for data conversion. [Data Export Procedures] (1) If using the USB memory, insert it into the USB port on the computer. (2) Select “Export”...
  • Page 30 [Procedures for Importing Data into the EB-50] (1) Click “Utility” then “Back up/import setting data” from the menu on the EB-50's Initial Setting Web browser to open the Back up/import settings screen. (2) Click the [Browse...] button to launch the explorer and browse for a file that contains the data to be imported.
  • Page 31 (4) When the settings data has been successfully imported, the EB-50 will restart.
  • Page 32: Error Message List

    6. Error Message List Message Explanation and Solution Appears when data import has failed. File import failed. Export the Initial Settings from the EB-50 again, and try importing the file again. Appears when an error occurred during data import. An issue occurred while importing. There may be cases where data import is possible, but an error may occur later while making the settings.
  • Page 33 Message Explanation and Solution Appears when importing data or when opening a saved file if the following conditions are met: ・The DIDO controller’s (DC) group is designated as an Output Units The setting contains mismatch kind that are whose “Allow Operation” setting is set to “No operation.” designated as input units or output units.
  • Page 34 MEMO...
  • Page 36 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT07019X01...