(N) Operation via communication and its settings
I/O signal list
• Remote I/O (64 points fixed)
Device
No.

RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
Jog operation selection
RYn5
(terminal Jog function)
Second function selection
RYn6
(terminal RT function)
Current input selection
RYn7
(terminal AU function)
Selection of automatic restart after
RYn8
instantaneous power failure
(terminal CS function)
RYn9
Output stop (terminal MRS function)
Start self-holding selection
RYnA
(terminal STOP function)
RYnB
Reset (terminal RES function)
RYnC to
RYnF
Reserved
RY(n+1)0 to
RY(n+1)F
RY(n+2)0
Monitor command
RY(n+2)1
Frequency setting command (RAM)
Frequency setting command
RY(n+2)2
(RAM, EEPROM)
RY(n+2)3
Torque command / torque limit (RAM)
Torque command / torque limit
RY(n+2)4
(RAM, EEPROM)
RY(n+2)5
Instruction code execution request
RY(n+2)6 to
Reserved
RY(n+3)9
RY(n+3)A
Error reset request flag
RY(n+3)B to
Reserved
RY(n+3)F

These signals are set in the initial values. Using Pr. 180 to Pr. 189, you can change input signal functions.
Refer to the Instruction Manual (Detailed) of the inverter for details of Pr. 180 to Pr. 189.

The signals are fixed. They cannot be changed using parameters.

These signals are set in the initial values. Using Pr. 190 to Pr. 196, you can change output signal functions.
Refer to the Instruction Manual (Detailed) of the inverter for details of Pr. 190 to Pr. 196.

Output signal can be assigned using Pr. 313 to Pr. 315.
The settings of Pr.313 to Pr.315 are the same as those of Pr.190 to Pr.196 (output terminal function selection).
Refer to the Instruction Manual (Detailed) of the inverter for details of Pr. 190 to Pr. 196.

"n" indicates a value determined according to the station number setting.
26
PARAMETER
Refer
Signal
page
30

30

30

30

30

30

30

30

30

30

30

30

30
30
30
30
30
30
30
Device
to
No.

RXn0
Forward running
RXn1
Reverse running
RXn2
Running (terminal RUN function)
RXn3
Up to frequency (terminal SU function)
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure
RXn5
(terminal IPF function)
Frequency detection
RXn6
(terminal FU function)
RXn7
Error (terminal ABC1 function)
RXn8
— (terminal ABC2 function)
RXn9 to
Reserved
RXnF
RX(n+1)0
Pr.313 assignment function (DO0)
RX(n+1)1
Pr.314 assignment function (DO1)
RX(n+1)2
Pr.315 assignment function (DO2)
RX(n+1)3 to
Reserved
RX(n+1)F
RX(n+2)0
Monitoring
RX(n+2)1
Frequency setting completion (RAM)
Frequency setting completion
RX(n+2)2
(RAM, EEPROM)
Torque command / torque limit setting
RX(n+2)3
completion (RAM)
Torque command / torque limit setting
RX(n+2)4
completion (RAM, EEPROM)
RX(n+2)5
Instruction code execution completion
RX(n+2)6 to
Reserved
RX(n+3)9
RX(n+3)A
Error status flag
RX(n+3)B
Remote station ready
RX(n+3)C to
Reserved
RX(n+3)F
Refer
Signal
to
page
31
31
31

31

31

31

31

31

31

31

31

31

31
31
31
31
31
31
31
31