Error reset operation selection at inverter fault (Pr.349)
• An error reset command from communication option can be invalid in the External operation mode or PU operation mode.
Use RY3A for an error reset command from network. (Refer to
Pr.349 setting
0 (initial value)
Error reset is enabled independently of operation mode
1
Error reset is enabled only in the network operation mode
100, 101
The status of Ready bit in communication data can be selected. (Refer to the Instruction Manual (Detailed).)

When the communication option is specified for the command source in Network operation mode, it is possible
1000, 1001, 1100, 1101
to select whether the inverter is reset after the "Fault reset" command is executed. (Refer to the Instruction

Manual (Detailed).)

Not available during operation via CC-Link IE TSN.
Operation mode switching and communication startup mode (Pr.79,
Pr.340)
• Check the following before switching the operation mode.
- The inverter is at a stop.
- Both the STF and STR signals are off.
- The Pr.79 Operation mode selection setting is correct. (Check the setting on the operation panel of the inverter.)
• The operation mode at power ON and at restoration from instantaneous power failure can be selected. Set a value other
than "0" in Pr.340 Communication startup mode selection to select the Network operation mode.
• After the inverter starts up in the Network operation mode, parameter write can be commanded via the network.
(Refer to
page 41
for a program example for parameter write.)
NOTE
• The changed value in Pr.340 is applied after the next power-ON or inverter reset.
• The Pr.340 setting can be changed on the operation panel in any operation mode.
• When setting a value other than "0" in Pr.340, make sure that the communication settings of the inverter are correct.
Parameters referred to
Pr.7 Acceleration time, Pr.8 Deceleration time, Pr.111 Third deceleration time
Pr.79 Operation mode selection
Pr.340 Communication startup mode selection
Instruction Manual (Detailed) of the FR-A800 inverter
Instruction Manual (Detailed) of the FR-A800 inverter
(N) Operation via communication and its settings
page
30.)
Description
Instruction Manual (Detailed) of the FR-A800 inverter
19
PARAMETER
2
GROUP