3-18
Chapter 3
Installing Printed Circuit Cards
8BSI CARD
The 8BSI(Base Station Interface) card must be inserted in slots 1,2 or 3 of same cabinet. If multiple 8BSI
cards are installed in an iDCS 500 L system then the 8BSI cards must be installed in the same cabinet.
Push firmly in the middle of the card to ensure that it is fully inserted into the back plane connector.
The Samsung iDCS 500 system receives it clock information from ISDN services connected so a PRI or
BRI card, where installed, must be installed in a lower slot number (e.g. C1-S1) than the 8BSI card.
However if ISDN circuits are not installed, the 8BSI card would normally be installed in slot 1 of the
iDCS 500 cabinet. The PRI supports ISDN PRI service. Push firmly in the middle of both card
ejectors on each card to ensure that it is fully inserted into the back plane connector. ISDN cards like
PRI and BRI use the external clock from the public network. So, when a SAMSUNG DECT system
use PRI or BRI, the system must align with the external clock as a slave. Also installed 8BSI card uses
the same clock as ISDN cards. So, the SAMSUNG DECT system determined the clock priority
according to the card type and the position of slot. At first, according to the second clock priority
and the 8BSI card has the lowest priority. In the next priority.
NOTE:
4E & M CARD
This card has the following options.
PORT1
PORT2
PORT3
PORT4
Insert as many E & M cards as are needed into any universal slots. Push firmly in the middle of
both card ejectors on each card to ensure that it is fully inserted into the back plane connector.
DLI CARD
There are no options to select on this card. Insert up to and including nine DLI cards per cabinet as
needed into any universal slots
each card to ensure that it is fully inserted into the back plane connector.
NOTE: If a cabinet is equipped with a single power supply unit (PSU-B), a maximum of 56 station
devices may be connected to that cabinet. However, if the cabinet is equipped with two power supply
units, a maximum of 120 station devices may be connected to that cabinet.
section of the General Description Guide for more details
Do not insert this card with system power ON.
A maximum of three 8BSI cards can be installed in slots 1,2 or 3 of same cabinet.
Normal
Tx
Rx
*ALL OFF
*ALL OFF
*ALL OFF
*ALL OFF
*ALL OFF
*ALL OFF
*ALL OFF
*ALL OFF
(see note below)
+34dB UP
Tx
Rx
J10 ON
J30 ON
J11 ON
J31 ON
J12 ON
J32 ON
J13 ON
J33 ON
. Push firmly in the middle of both card ejectors on
.
+6.0dB UP
Tx
Rx
J10, J20 ON
J30, J40 ON
J11, J21 ON
J31, J41 ON
J12, J22 ON
J32, J42 ON
J13, J31 ON
J33, J43 ON
See the configuration