Parameter Setting Overview And Flowmeter Design Options - ABB MAG-SM Instruction Bulletin

Field mount housing and 19“-design
Table of Contents

Advertisement

Electromagnetic Flowmeter Converter

10. Parameter Setting Overview and Flowmeter Design Options

Meter Location:
Primary Type:
Order No.:
Fluid Temp.:
Liner:
C:
Parameter
Prog. Protection Code
Language
Flowmeter Primary:
Meter Size:
Q
:
max
Pulse Factor:
Pulse Width:
Low Flow Cutoff:
Damping:
Filter:
Density:
Units Q
:
max
Totalizer Units:
Max. Alarm
Min. Alarm
Terminals P1/P2:
Terminals P3/P4:
F/R-Contact 44/45/46
Current Output:
I
at Alarm:
out
Detector e. Pipe:
Alarm e. Pipe:
I
at e. Pipe:
out
Threshold:
Adjust e. Pipe:
1st Display Line:
2nd Display Line:
1st Line Multiplex:
2nd Line Multiplex:
Operating Mode:
Flow Direction:
Direction Indication:
Store data in ext. EEPROM
Pulse output:
Communication:
Detector empty pipe:
Alarm:
Ext. zero return:
52
Instrument No.:
Electrodes:
Setting Range
0–255 ( 0 = factory setting)
German, English, French, Finnish, Spanish, Italian,
Dutch, Danish, Swedish
10DS2110/3110, DS21, DS41, DS41 > 12"[DN 300], DH,
10DI1425 <20"[DN 500]; 10DI1425 >16"[DN 400], 10DS3111 E > 12"[DN 300]
10D1422, 10D1462/1472
1/25" - 40" [DN 1 – 1000]
0.05 Range
0.01 to 1000 pulses/Eng'g unit
0.032 – 2000 ms
0 – 10 % of flow range end value
0.125 – 99.99 seconds
ON/OFF
0.01 g/cm
l/s, l/min, l/g,hl/s, hl/min, hl/h, m3/s, m3/min, m3/h, igps, igpm,igph,
mdg, gpm, gph, bbl/s, bbl/min, bbl/h, bls/day, bls/min, bls/h, kg/s,
g/min, kg/h, t/s, t/min, t/h, g/s, g/min, g/h, ml/s, ml/min, ml/h, MI/min,
MI/h, MI/day, lb/s, lb/min, lb/h, uton/min, uton/h, uton/day,
kgal/s, kgal/min, kgal/h
l, hl, m3, igal, gal, mgal, bbl, bls, kg, t, g, ml, MI, lb, uton, kgal
%
%
Alarm MAX
Alarm MIN
Forward/reverse flow direction signal
0/4–20 mA, 0/2–10 mA, 0–5 mA, 0–10–20 mA, 4–12–20 mA
0 %, 3.6 mA Max. I
ON/OFF
ON/OFF
0 %, 3.6 mA Max. I
0–100
Software potentiometer value
Q (%), Q (units), Q (mA), Q (m/s), totalizer F/R,
difference totalizer, TAG-Number, bargraph
Q (%), Q (units), Q (mA), Q (m/s), totalizer F/R,
difference totalizer, TAG-Number, blank line, bargraph
ON/OFF
ON/OFF
Standard/piston pump
Forward/reverse, forward
Normal, Inverse
Yes/No
Active
HART-Protocol
Yes
Yes
Yes Ext. totalizer reset
TAG-No.:
Converter Type
Order No.:
Voltage Supply:
Excitation Frequency:
System Zero:
to 1.5 Range
max
max
3
3
– 5.0 g/cm
(100 %, 115 %, 130 %)
out
(100 %, 115 %, 130 %)
out
Passive
RS 485
No
No
Yes Ext. zero compensation
Instrument No.:
V
Hz
Hz
Profibus DP
Yes Ext. zero return

Hide quick links: