ABB MAG-SM Instruction Bulletin page 35

Field mount housing and 19“-design
Table of Contents

Advertisement

Communication Protocol Profibus DP per DIN 19245
Communication during on-line operation using stadardized
Profibus DP Process Control technology. A list of the supported
communication objects and their definitions can be requested.
The cable types described in DIN 19245, Part 1 and Part 3 are
generally used for this communication technology, see Part 3,
Table 3 and Table 4.
Terminal Designations:
Terminal Function
V1
B RxD/TxD-P
V2
A RxD/TxD-N
V4
VP
G2
C DGND
Shield connected to housing
Cable
A shielded and twisted data cable is recommended.
Max. cable length 1200 m (Cable type A)
Characteristic impedance 135-165 Ohm
Max. 32 instruments per segment
Max. 124 instruments on a single bus, total
Baudrate: 9.6-1500 kbit/s
Distributed capacitance <30 pF/m, loop resistance 110 Ω/km
Max. tap line length 1 m.
In- and outgoing cables connected to the same terminals.
PNK
(SPS)
With Bus
W ith Bus
Terminator
Term inator
Converter
1
Fig.12
Bus Termination Profibus DP
Cable Terminations:
Both ends of the bus cable must be provided with a bus
termination. In addition to the bus termination resistor R2
specified in the EIA-RS-485 Standard an additional resistor R1
(Pull-down) must be connected to the data reference
potential DGND and a resistor R3 (Pull-up) connected to the
supply voltage plus VP. These two resistors are used to define
a specific idle potential on the bus when no participant is
transmitting (idle time between telegrams, the so called
idle-status).
Values see DIN 19245, Part 1 and Part 3.
For cable Type A:
R
= 390
1
For cable Type B:
R
= 390
1
Reference
Receive/send data - P
Receive/send data - N
Supply voltage Plus P5V
Data refernce potential; M5V
Converter
Converter
2
3
With Bus Termination
, R
= 220
, R
= 390
2
3
, R
= 150
, R
= 390
2
3
Electromagnetic Flowmeter Converter
3 1S 1
2 2S 3 16
Fig.13
Bus Termination for Profibus DP, when the Instrument is
Connected at the End of the Bus
GSD File (Instrument Data Base)
The name of the GSD file is ABB_6666.GSD and is included
with the shipment. For a detailed description of the Data Link
see the separate Document ABB Part No. D184B093U03.
6
4
A902
A903 A901 A904
6
7
15 +
- M1M3
V5
V6 44 45 46 P1 P2 P3 P4
G2
V1
V2
V3
V4
U2
22
31
A1
A2
R1
R2
R3
L
N
PE
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50sm1000