Download Print this page
Timeguard Theben Termina TR 612 top Manual
Timeguard Theben Termina TR 612 top Manual

Timeguard Theben Termina TR 612 top Manual

2-channel 7 day timers

Advertisement

Quick Links

TR 612 top
TERMINA
2-channel 7 day timers
Safety
Safety
Information
Information
The connection and installation of electrical
appliances must be performed by a skilled
electrician only. Any intervention into or
modifications to the appliance shall lead to
the lapse of all warranty rights. Comply with
your national regulations and all relevant
safety stipulations.
D
GB
F
NL
I
E
Overview per day of
the programmed swit-
ching times
5 = Friday
Channel statuses
C1 or C2 are displayed
alternately ON / OFF
Service voltage OK:
Two flashing dots.
Power reserve mode:
Three flashing dots.
Selection
Prog, n, Man,
e.g.: Auto,
Abort input
P
Display of special functions:
Hand ON/OFF
Permanent ON/OFF
Displayed only when summer/
winter time changeover is
activated
Summer time r
Winter time f
Current days of the week
1 = Monday, 2 = Tuesday, ...
The decision Yes confirms the
selection or programming
Decision No means continue
310 791 03

Advertisement

loading
Need help?

Need help?

Do you have a question about the Theben Termina TR 612 top and is the answer not in the manual?

Questions and answers

Summary of Contents for Timeguard Theben Termina TR 612 top

  • Page 1 310 791 03 TR 612 top Display of special functions: Overview per day of the programmed swit- Hand ON/OFF TERMINA • ching times Permanent ON/OFF 5 = Friday 2-channel 7 day timers Displayed only when summer/ Channel statuses winter time changeover is C1 or C2 are displayed activated alternately ON / OFF...
  • Page 2: Fir St Contact

    st contact st contact For programming, viewing or deleting First of all read the text display. Info Info Menu selection The timer is delivered in so-called sleep mode. To Select by pressing the Prog key. Confirm by pressing increase the power reserve the switch clock changes to By pressing the key select the desired menu.
  • Page 3 Degree of protection II EN 60730 IP 20 EN 60529 Type 1 BSTU memory IEC/EN 60730-2-7 locations...
  • Page 4 amming the switching time amming the switching time Switching times for lighting systems, machines, Formation of day groups ventilation systems, alarm systems etc. If the same switching times are active on Example Example several days of the week, they occupy just one memory location, e.g.
  • Page 5 Override Override ermanent ON or OFF ermanent ON or OFF Via the automatic menu Individual deletions Auto only Channel Channel Press the Manual preselection: Manual preselection: Press keys simultaneously. Press keys simultaneously. two keys for Channel C1 switches Channel C2 switches approx.
  • Page 6 Setting/ corr ecting the date and time Setting/ corr ecting the date and time summer/winter time summer/winter time Automatic summer/winter time Read the text display first correction of all. According to version the timer is pre- Select by pressing the programmed ex-works complete with key.
  • Page 7 Select WITHOUT PIN using oder Confirm with the button. TIMEGUARD LTD., Victory Park, 400 Edgware Road, PETER WARBURTON PTY. LIMITED, 64 Brittania Road, Castle Hill London NW2 6ND NSW 2154, Australia, Tel.: (02) 9899 2908, Fax: (02) 9899 4486 Tel. 0208/4508944, Fax 0208/4525143...