Advertisement

[8]
Select setup 2
[9]
Select setup 3
[10]
Select setup 4
NB!
The following configuration is required in order to change the set-up after a time-out:
Set par. K-10 Active Set-up to [9] Multi set-up and select the relevant link in par. K-12 This Set-up Linked to.
O-05 End-of-Timeout Function
Option:
6
[0]
Hold set-up
[1] *
Resume set-up
O-06 Reset Control Word Timeout
This parameter is active only when Hold set-up [0] has been selected in par. O-05 End-of-Timeout Function.
Option:
[0] *
Do not reset
[1]
Do reset
O-10 Control Word Profile
Select the interpretation of the control and status words corresponding to the installed network. Only the selections valid for the network installed in slot A will
be visible in the Keypad display.
For guidelines in selection of GE Drive profile [0] and PROFIdrive profile [1] please refer to the Serial communication via RS 485 Interface section.
For additional guidelines in the selection of PROFIdrive profile [1], ODVA [5] and CANopen DSP 402 [7], please refer to the Operating Instructions for the installed
network.
Option:
[0] *
Drive Profile
O-13 Configurable Status Word STW
Option:
[0]
No function
[1] *
Profile Default
[2]
Alarm 68 Only
[3]
Trip excl Alarm 68
[16]
T37 DI status
34
fines whether to resume the set-up used before the time-out or to retain the set-up endorsed by the time-
out function.
See [7] Select setup 1
See [7] Select setup 1
See [7] Select setup 1
Function:
Select the action after receiving a valid control word following a time-out. This parameter is active only
when par. O-04 Control Word Timeout Function is set to [Set-up 1-4].
Retains the set-up selected in par. O-04 Control Word Timeout Function and displays a warning, until
par. O-06 Reset Control Word Timeout toggles. Then the drive resumes its original set-up.
Resumes the set-up active prior to the time-out.
Function:
Retains the set-up specified in par. O-04 Control Word Timeout Function, following a control word time-
out.
Returns the frequency converter to the original set-up following a control word time-out. The frequency
converter performs the reset and then immediately reverts to the Do not reset [0] setting
Function:
Function:
This parameter enables configuration of bits 12 – 15 in the status word.
Function corresponds to the profile default selected in par. O-10 Control Word Profile.
Only set in case of an Alarm 68.
Set in case of a trip, except if the trip is executed by an Alarm 68.
The bit indicates the status of terminal 37.
"1" indicates T37 is high (normal)
OPCEIP EtherNet/IP