10.3 PLC Constants
#
PLC device
6301
R2800,2801
6348
R2894,2895
#
PLC device
6349
R4900,4901
6396
R4994,4995
10.4 Selecting the PLC Bit
#
PLC device
6401
R2900-Low
6402
R2900-High
6495
R2947-Low
6496
R2947-High
#
PLC device
6497
R4400-Low
6498
R4400-High
6595
R4449-Low
6596
R4449-High
10. PLC Constants
10.3 PLC Constants
(SETUP PARAM 6. 4/14)
Item
PLC constant
Set the value to be set in the data type R
register used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
(SETUP PARAM 6. 5/14)
Item
PLC constant
Set the value to be set in the data type R
register used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
(SETUP PARAM 6. 6/14) to (SETUP PARAM 6. 7/14)
Item
Bit selection
This is the bit type parameter used in the
PLC program (ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
Some of the parameters following #6449
may be fixed according to the usage
purpose.
Refer to the PLC Program Development
On-board Instruction Manual.
(SETUP PARAM 6. 7/14) to (SETUP PARAM 6. 9/14)
Item
Bit selection
This is the bit type parameter
expansion
(expansion) used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
Details
Details
Details
Details
II - 317
Setting range
-99999999
to 99999999
Setting range
-99999999
to 99999999
Setting range
0: OFF
1: ON
Setting range
0: OFF
1: ON
Need help?
Do you have a question about the MELDAS 60 Series and is the answer not in the manual?
Questions and answers
we replaced MDS-B-SPJ2 spindle drive by MDS-B-SPJ2-110. Then problem occurred related spindle RPM . If spindle rpm given is 500 Then it actually showing 348. is there any parameter setting ?
The parameter settings for the Mitsubishi Electric MELDAS 60 Series after replacing the MDS-B-SPJ2 spindle drive with the MDS-B-SPJ2-110 to correct spindle RPM discrepancies must match the correct spindle parameters based on the motor and amplifier type. After setting the parameters, the NC power must be turned OFF and then ON again for the changes to take effect. The specific parameters to be adjusted should be referenced using the spindle parameter tables in the manual corresponding to the MDS-B-SPJ2 model.
This answer is automatically generated