Timing chart of I/O signals
■When the FB completed successfully
i_bEN
o_bENO
Command send processing
o_bOK
o_bErr
o_uErrId
■When the FB completed with an error
i_bEN
o_bENO
Command send processing
o_bOK
o_bErr
o_uErrId

Error codes

Error code
Description
C1E0H
• Effective range error (Connection No./User name/Password)
The set data is out of effective range: i_uConnectionNo is not set within
1 to 16; i_sUsername is not set within 4 to 14 characters; or
i_sPassword is not set within 4 to 64 characters.
C1E2H
• Timeout error
No response is returned from the network camera after the command is
sent.
C1E3H
• User name/password setting error
Unregistered i_sUsername or i_sPassword is set.
Other than the
Errors that occur in each processing for data communication between
above
the Ethernet-equipped module and external device, and errors that
occur in processing requests from the CPU module in the own station
7 FB LIBRARY DETAILS
44
7.1 M+CameraRecord_AXIS_SetTime_R
ON
OFF
ON
OFF
Performed
Not performed
OFF
OFF
0
ON
OFF
ON
OFF
Not performed
Not performed
Performed
OFF
ON
OFF
0
OFF
OFF
Not performed
ON
OFF
OFF
OFF
OFF
Error code
0
Action
Review and correct the input label, and execute the FB again.
Review and correct the following, and execute the FB again.
• When the constant scan time exceeding 500ms is set, set it
• Set the same IP address in the specified connection
Review and correct the input label, and execute the FB again.
 MELSEC iQ-R Ethernet User's Manual (Application)
to 500ms or less, or leave it blank.
number as that of the network camera.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents