Mitsubishi Electric MELSEC iQ-R Series User Manual page 35

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Input label
i_bEN
i_uConnectionNo
i_sUsername
i_sPassword
i_uVirtualInputPortNo
i_bVirtualInputPortState
Output label
o_bENO
o_bOK
o_bErr
o_uErrId
If recording events occur consecutively in a brief period of time and the recording duration of one event
overlaps the recording duration of the subsequent event, this FB may not be completed successfully and a
timeout error (C1E2H) may occur. Ensure that the recording durations of events do not overlap when this FB
is executed.
Setting details
Connects with a device used as a recording trigger.
On: The FB is activated (a recording event is executed).
Off: The FB is stopped.
Sets the connection number.
Sets the user name registered in the network camera.
Sets the password registered in the network camera.
Specifies the port number of the virtual input for the recording event registered in the network camera.
Sets the virtual input port status.
On: The virtual input port status is enabled.
Off: The virtual input port status is disabled.
To activate the trigger, enable the virtual input port status. The virtual input port status cannot be automatically
disabled once it has been enabled. Therefore, disable the virtual input port status after the event is started.
Setting details
On: The execution command is on.
Off: The execution command is off.
The on state indicates that the virtual input port status on the network camera side has been switched.
The on state indicates that an error has occurred in the FB.
Returns the error code of an error occurred in the FB.
4 INSTALLATION AND SETTINGS