Mute Switching; Output Level Control; Scene Recall - Yamaha 1009MWTO-F0 Owner's Manual

Yamaha digital mixing engine owner's manual
Table of Contents

Advertisement

Mute Switching

Turns the DME64N/24N output mute function ON or OFF.
1.
Press the [MUTE] button.
The Mute Parameter Edit display will appear.
2.
Select Mute ON or OFF.
The mute function is turned on or off as described
in "ON/OFF Parameters" on page 38.
NOTE
To access this function from the ICP1 control panel, hold
the [F6] button for longer than 2 seconds.
NOTE
All outputs in the device group, including the [PHONES]
jack, are muted.

Output Level Control

Adjust the output level of the DME64N/24N.
NOTE
Output level settings apply individually to each DME64N/
24N unit. There is no overall device group setting.
This function cannot be accessed from the ICP1 control
panel.
1.
Press the [LEVEL] button.
The "Output Level" Parameter Edit display will
appear.
2.
Adjust the numeric output level parameter
as required.
The Output Level parameter is adjusted as
described in "Numeric Parameters" on page 36.
The graphic fader provides a visual indication of the
current output level setting.

Scene Recall

This procedure recalls a new scene (refer to page 10).
NOTE
The same procedure is used for scene recall from an ICP1
control panel.
1.
Press the [SCENE] button.
The Scene Recall display will appear.
2.
Select a new scene.
Scenes are selected as described in the "List
Parameters" section on page 38.
3.
Press the [ENTER] button.
A confirmation window will appear.
4.
Press the [ENTER] button again.
The new scene will be selected.
Don't turn the power off during a scene recall
operation. Doing so can cause corruption of
CAUTION
the current scene data.
DME64N/DME24N Owner's Manual
Parameter Edit Displays
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme64nDme24n

Table of Contents